Fire Hazard / Electric
Shock Hazard
Do not use this water heater with
any voltage other than shown on the
model rating plate.
Failure to use the correct voltage
shown
on the model rating plate
could result in death, serious bodily
injury, or property damage.
Before making the conversion to 5500 watts, make sure that the
(1) power supply is 240 volts, (2) the wiring is 10 gauge AWG
@ Type TW, 60°C or equivalent,
and (3) the circuit breakers
or fusing are capable of 30 amp loading. Also, the installation
must conform with this manual, local codes and electric utility
rules. Failure to comply can result in DEATH, SERIOUS BODILY
INJURY, OR PROPERTY DAMAGE.
ELECTRIC
Q
LISTED
WATER HEATER
932N
CAPACITY
MODEL
NUMBER
U.S.
GAL.
SERIAL
NUMBER
FACTORY
EQUIPPED
WITH
MAXIMUM
UPPER
LOWER
CHECK
HERE
WORKING
ELEMENT
ELEMENT
MAXIMUM
VOLTS
IF INSTALLED
AS
PRESSURE
WATTS
WATTS
WATTS
A.C.
ONLY
FACTORY
EQUIPPED
P.S.L
OPTIONAL
WATTAGE
UPPER
LOWER
ELEMENT
ELEMENT
MAXIMUM
CHECK
HERE
WATTS
WATTS
WATTS
IF CONVERTED
WARNING
SEE CONVERSION
INSTRUCTION
FIGURE 6.
NOTE: Whether or not the element conversion
is made the
model rating plate must be marked. Using a hard point ink pen,
check the appropriate block within the model rating plate, which
is located adjacent to the lower access panel.
Water Piping
mT_I ((el = (!
Water
temperature
over
125°F
(52°C) can cause severe
burns
instantly resulting in severe injury
or death.
Children,
the
elderly,
and
the
physically
or mentally
disabled
are at highest riskfor scald injury.
Feel
water
before
bathing
or
showering.
Temperature
limiting valves
are
available.
Read instruction
manual for safe
temperature setting
HOTTER WATER CAN SCALD: Water heaters are intended
to produce hot water. Water heated to a temperature
which
wilt satisfy clothes washing, dish washing, and other sanitizing
needs can scald and permanently injure you upon contact. Some
people are more likely to be permanently
injured by hot water
than others. These include the elderly, children, the infirm, or
physically/mentally
handicapped.
If anyone using hot water in
your home fits into one of these groups or if there is a local code
or state law requiring a certain temperature water at the hot water
tap, then you must take special precautions. In addition to using
the lowest possible temperature
setting that satisfies your hot
water needs, a means such as a mixing valve should be used at
the hot water taps used by these people or at the water heater.
Mixing valves are available
at plumbing
supply or hardware
stores. Follow manufacturers
instructions for installation of the
valves. Before changing the factory setting on the thermostat,
read the "Temperature Regulation" section in this manual.
See Figure 7 (below) for mixing valve usage.
f
HOT
WATER
OUTLET
COLD
WATER
INLET
TEMPEREC
WATER
OUTLET
*MIXING
VALVE
TO COLD
WATER
t
_
INLET
ON
WATER
HEATER
FROM
HOT
WATER
OUTLET
ON
WATER
HEATER
FIGURE 7.
Figure 8 shows the attachment of the water piping to the water
heater. The water heater is equipped with 3/4" water connections.
If a water heater is installed in a closed water supply system;
such as one having a back-flow preventer, check valve, water
meter with a check valve, etc.., in the cold water supply; an
expansion
tank or other means must be provided to control
thermal expansion.
Contact the local utility or Sears Service
Center on how to control this situation. See "Thermal Expansion."
Also, the water supply pressure should
not exceed 80 psi.
If this occurs, a pressure reducing valve with a bypass should
be installed in the cold water inlet line. This should be placed
on the supply to the entire house in order to maintain equal hot
and cold water pressures.
NOTE: If using copper tubing, solder tubing
to an adapter
before attaching
the adapter
to the water inlet connection.
Do not solder
the water supply
lines directly
to the cold
water inlet.
It will harm the dip tube and damage the tank.
Property
Damage
Hazard
• Avoid water heater damage.
• Install thermal expansion tank if necessary.
• Do not apply heat to cold water inlet.
• Contact qualified installer or service agency.