Diaphragm; Horizontal Intake-Exhaust Kit - Immergas EOLO Mini S Instruction Booklet

Table of Contents

Advertisement

Positioning of double-lip seals. For correct po si tion ing of
ES
the lip seals on elbows and extensions, follow the order of
assembly shown in the fi gure.
PL
CZ
HR
SL
HU
Diaphragm installation. To ensure correct op er a tion of the
IE
boiler, a diaphragm (see fi gure) must be in stalled on output
of the sealed chamber before the intake and exhaust duct.
Selection of a suitable di a phragm depends on the type of
ducting used and maximum length: calculations can be made
using the values in the tables below:

DIAPHRAGM

N.W.: Diaphragms are supplied as standard with the boi-
ler.
DIAPHRAGM
Ø 41,5
NONE
DIAPHRAGM
Ø 41,5
NONE
*  e values for maximum length are considered with 1 metre
of exhaust pipe and the remaining on in take.
106
Duct length in metres
Ø 60/100 horizontal
From 0 to 1
Over 1
Duct length in metres
Ø 60/100 vertical
From 0 to 2.7
Over 2.7
DIAPHRAGM
Ø 80 horizontal duct with two bends
Ø 41,5
NONE
DIAPHRAGM
Ø 80 vertical duct without bends
Ø 41,5
NONE
DIAPHRAGM
Ø 41,5
NONE
DIAPHRAGM
Ø 41,5
NONE
Horizontal intake-exhaust kit Ø60/100. Kit as sem bly:
install the bend with fl ange (2) on the central hole of the
boiler taking care to insert the seal (1) and secure by means of
the screws supplied with the kit. Join the male end (smooth
section) of ter mi nal pipe (3) to the female section (with lip-
seal) of bend (2) to the end stop and ensure that the in ter nal
and ex ter nal washers are fi tted to achieve per fect seal ing of
all couplings.
• Snap-fi t couplings of concentric pipes or ex ten sions and
elbow fi ttings Ø60/100. To install extension cou plings
on other fl ue extraction components, pro ceed as follows:
fi t the concentric pipe or con cen tric elbow with the male
section (smooth) on the female section (with lip-seal) of
the previously in stalled component to the end stop to
ensure per fect sealing of the coupling.
*Duct length in metres
From 0 to 20
Over 20
*Duct length in metres
From 0 to 25
Over 25
Duct length in metres
Ø 80/125 horizontal
From 0 to 1.9
Over 1,9
Duct length in metres
Ø 80/125 vertical
From 0 to 6.8
Over 6,8
 e kit comprises:
1 - Seal (1)
1 - Concentric 90° bend (2)
1 - Intake/exh. concentric pipe
Ø60/100 (3)
1 - Internal washer (4)
1 - External washer (5)