 e horizontal intake-exhaust kit Ø 60/100 can be installed
with a rear, right-hand, left-hand, or front out let as requi-
red.
• Application with rear outlet.  e 970 mm pipe length
enables partial routing through a maximum thick ness 770
mm. Normally the terminal should be short ened. Calcu-
late the distance by adding the fol low ing: Part thickness
+ internal protrusion + ex ter nal protrusion. Minimum
protrusion values are given in the fi gure below.
• Application with lateral outlet; Using the horizontal intake-
exhaust kit only, without the special ex ten sions, enables
routing through a wall thickness of 725 mm with the
left-hand outlet and 635 with the right-hand outlet.
• Extensions for horizontal kit.  e horizontal in take-
exhaust kit Ø 60/100 can be extended up to a max. hori-
zontal distance of 3000 mm including the grille terminal
and excluding the concentric bend on out put of the boiler.
 is confi guration cor re sponds to a resistance factor of
100. In this case special ex ten sions must be requested.
Connection with 1 extension. Max. distance be tween
vertical boiler axis and external wall: 1855 mm.
Connection with 2 extensions. Max. distance be tween
vertical boiler axis and external wall 2805.
Horizontal intake-exhaust kit Ø 80/125. Kit as sem bly:
install the bend with fl ange (2) on the central hole of the
boiler taking care to insert the seal (1) and tighten with the
screws supplied in the kit. Fit the adapt er (3) with the male
section (smooth) in the fe male section of the bend (2) (with
lip seal) to the end stop. Fit the concentric terminal Ø 80/125
(4) with the male section (smooth) in the female section of
the adapter (3) (with lip seal) to the end stop, en sur ing that
the internal and external washers are fi t ted to ensure sealing
effi ciency of all couplings.
• Snap fi t extension pipe fi ttings and concentric el bows Ø
80/125. To install snap-fi t ex ten sions with other elements
of the boiler assembly, pro ceed as fol lows: fi t the concentric
pipe or elbow with the male sec tion (smooth) on the female
sec tion (with lip seal) to the end stop on the previously
installed to ensure sealing effi ciency of the cou pling.
Caution: if the exhaust terminal and/or extension concen-
tric pipe needs shortening, consider that the internal duct
must always protrude by 5 mm with re spect to the external
duct.
Normally the horizontal intake/exhaust kit Ø 80/125 is used
in the event of using particularly long ex ten sions; the kit Ø
80/125 can be installed with a rear, right-hand, left-hand
or front outlet.
 e kit comprises:
1 - Seal (1)
1 - Concentric bend
Ø 60/100 (2)
1 - Adapter Ø 60/100 for Ø
80/125 (3)
1 - Concentric int./exh. bend
Ø 80/125 (4)
1 - Internal washer (5)
1 - External washer (6)