Viking Range Corporation
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For product information,
call 1-888-VIKING1 (845-4641)
or visit the Viking Web site at
vikingrange.com
Designer Hoods
U L
U L
C
F20472D EN
(022410)

Advertisement

Table of Contents
loading

Summary of Contents for Viking DCWH Classic Chimney

  • Page 1 Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.com Designer Hoods F20472D EN (022410)
  • Page 2: Table Of Contents

    All Viking ventilator kits are or ceilings, or into attics, crawl spaces, or Exterior Ventilator Dimensions _____________________________________________________________________27 designed specifically for use with Viking hoods. Use of any garages. DBCV Wall Custom Ventilator System non-Viking ventilator kit will void the hood warranty.
  • Page 3: Dch 12"H. Classic Chimney Wall Hoods W/Standard Ventilator

    Dimensions & Specifications IMPORTANT– Please Read and Follow! (DCH 12”H. Classic Chimney Wall Hoods w/Standard Ventilator) W A R N I N G ” ( 4 0 TO REDUCE THE RISK OF INJURY TO PERSONS ” ( 3 0 IN THE EVENT OF A RANGETOP GREASE FIRE, OBSERVE THE FOLLOWING.
  • Page 4: Clearance Dimensions

    Clearance Dimensions Interior Ventilator Dimensions (DCH 12”H. Classic Chimney Wall Hoods w/Standard Ventilator) (DCH 12”H. Classic Chimney Wall Hoods w/Standard Ventilator) Top view 16” (40.6 cm) 4” ” m ( 1 6 ” m i n . ( 7 6 7 .
  • Page 5: Dimensions & Specifications

    Dimensions & Specifications Installing Hood Canopy (DPPV Custom Power Packs w/Standard Ventilator System) (Custom Hood Canopy Cutouts C C u u s s t t o o m m H H o o o o d d C C a a n n o o p p y y *For best results, M M a a k k e e s s u u r r e e t t h h e e b b a a c c k k w w a a l l l l center the unit over...
  • Page 6: Clearance Dimensions

    Clearance Dimensions Interior Ventilator Dimensions (DPPV Custom Power Packs w/Standard Ventilator System) (DPPV Custom Power Packs w/Standard Ventilator System) Top view ( C u s t o 16” (40.6 cm) 4” 30”W. 14-15/16” (37.9 cm) (10.2 cm) ” m ( 1 6 ”...
  • Page 7: Dcwh/Dcwn/Dcwl Classic Chimney Wall Hoods

    Clearance Dimensions Dimensions & Specifications (DCWH Classic Chimney Wall Hoods 30”, 36”, 42”, & 48”) (DCWH/DCWN/DCWL Classic Chimney Wall Hoods) (DCWN Ledgeless models 30”, 36”, 42”, & 48”) (DCWL Ledge models 33”, 39”, 45”, & 51”) ” A (Duct cover width) D (Duct height) 30”W.
  • Page 8: Interior Ventilator Dimensions

    Interior Ventilator Dimensions Exterior Ventilator Dimensions (DCWH/DCWN/DCWL Classic Chimney Wall Hoods) (DCWH/DCWN/DCWL Classic Chimney Wall Hoods) Top view Top view C (Duct diameter) 1-1/2” 1-1/2” 30”W. 10” (25.4 cm) 30”W. 10” (25.4 cm) 30”W. 8” (20.3 cm)* 1-1/2” (3.8 cm) 1-1/2”...
  • Page 9: Dcih Classic Chimney Island Hoods 36", 42

    Dimensions & Specifications Clearance Dimensions (DCIH Classic Chimney Island Hoods) (DCIH Classic Chimney Island Hoods 36”, 42”, & 54”) ” A (Duct cover width) C (Duct height) ( 3 0 36”W. 12” (30.5 cm) 16” (40.6 cm) 36”W. 42”W. 12” (30.5 cm) 28”...
  • Page 10: Interior Ventilator Dimensions

    Interior Ventilator Dimensions Exterior Ventilator Dimensions (DCIH Classic Chimney Island Hoods) (DCIH Classic Chimney Island Hoods) Top view Top view 12” 12” (30.5 cm) (30.5 cm) 4-3/4” 36”W. 17-15/16” (45.6 cm) 36”W. 17-15/16” (45.6 cm) (12.1 cm) 4-3/4” 42”W. 20-15/16” (53.2 cm) 42”W.
  • Page 11: Dtws Slim Traditional Wall Hoods 30", 36", 42

    Dimensions & Specifications Clearance Dimensions (DTWS Slim Traditional Wall Hoods 30”, 36”, 42”, & 48”) (DTWS Slim Traditional Wall Hoods) ” A (Duct cover width) ( 3 0 30”W. 12” (30.5 cm) 36”W. 12” (30.5 cm) 42”W. 12” (30.5 cm) ”...
  • Page 12: Interior Ventilator Dimensions

    Interior Ventilator Dimensions Exterior Ventilator Dimensions (DTWS Slim Traditional Wall Hoods) (DTWS Slim Traditional Wall Hoods) Top view Top view 5-9/16” 5-9/16” 1-1/8” (14.3 cm) (14.3 cm) 1-1/8” (2.9 cm) (2.9 cm) 5-1/8” 5-1/8” (13.0 cm) (13.0 cm) 30”W. 15-3/4” (40.0 cm) 30”W.
  • Page 13: Dtwn Tall Traditional Wall Hoods-Ledgeless 30", 36", 42

    Clearance Dimensions Dimensions & Specifications (DTWN Tall Traditional Wall Hoods— (DTWN Tall Traditional Wall Hoods) Ledgeless 30”, 36”, 42”, & 48”) A (Duct cover width) 30”W. 29-7/8” (75.9 cm) 36”W. 35-7/8” (91.1 cm) 42”W. 41-7/8” (106.4 cm) 48”W. 47-7/8” (121.6 cm) 2 ”...
  • Page 14: Interior Ventilator Dimensions

    Interior Ventilator Dimensions Exterior Ventilator Dimensions (DTWN Tall Traditional Wall Hoods) (DTWN Tall Traditional Wall Hoods) Top view Top view 8-1/4” 18-3/4” (47.6 cm) (20.9 cm) A (Duct diameter) 4-5/8” 5-5/16” A (Duct diameter) 6-7/16” 9-1/8” (11.7 cm) (16.4 cm) (15.1 cm) VIV300 7”...
  • Page 15: Dbcv Wall Custom Ventilator System

    Dimensions & Specifications Installing Hood Canopy (Custom Hood Canopy Cutouts (DBCV Wall Custom Ventilator System) C C u u s s t t o o m m H H o o o o d d *For best results, M M a a k k e e s s u u r r e e t t h h e e b b a a c c k k w w a a l l l l C C a a n n o o p p y y o o f f t t h h e e c c u u s s t t o o m m h h o o o o d d center the unit over...
  • Page 16: Clearance Dimensions

    Built-In Wall Custom Ventilator Clearance Dimensions System Dimensions (DBCV Wall Custom Ventilator System) (30”W./36”W./42”W. DBCV Models 11” 11” (27.9 cm) (27.9 cm) 8” 7” (20.3 cm) (17.8 cm) 1” 1” (2.5 cm) (2.5 cm) ( C u s t o 11-3/4”...
  • Page 17: Dicv Island Custom Ventilator System

    Dimensions & Specifications Built-In Wall Custom Ventilator System Dimensions (DICV Island Custom Ventilator Systems 36”, 42”, & 54”) (48”W. DBCV Models 11” (27.9 cm) 10” (25.4 cm) 1” (2.5 cm) *For best results, M M a a k k e e s s u u r r e e t t h h e e b b a a c c k k w w a a l l l l center the unit over o o f f t t h h e e c c u u s s t t o o m m h h o o o o d d 11-3/4”...
  • Page 18: Installing Hood Canopy

    Clearance Dimensions Installing Hood Canopy (DICV Island Custom Ventilator System) (Custom Hood Canopy Cutouts C C u u s s t t o o m m H H o o o o d d ( C u s t o C C a a n n o o p p y y ”...
  • Page 19 Built-In Island Custom Ventilator Built-In Island Custom Ventilator System Dimensions System Dimensions (36”W./42”W. DICV Models (54”W. DICV Models 11” 11” 11” (27.9 cm) (27.9 cm) (27.9 cm) 8” 7” 10” (20.3 cm) (17.8 cm) (25.4 cm) 1” (2.5 cm) 1” (2.5 cm) 1”...
  • Page 20: Planning Information

    Installation (DCH 12”H. Classic Chimney Wall Hoods w/Standard Ventilator and DPPV Custom Power Packs w/Standard Ventilator) Planning Information Plan where the duct work will be located. Install 300 or 600 CFM proper-sized duct work, roof, or wall cap for the Roof cap single blower interior-power...
  • Page 21: Duct Cover Option (Dch 12"H. Classic Chimney Wall Hoods W/Standard Ventilator)

    Slide filter front over front lip. Push filter rear up, then CAUTION: If not using a duct cover, using screws CAUTION: Secure vent hood to wall using screws slide back over rear lip. provided. Use additional mounting screws and wall provided make sure top mounting screws are secured anchors, if necessary.
  • Page 22: Installation (Dch 12"H. Classic Chimney Wall Hoods W/Recirculating Kit)

    Installation (DCH 12”H. Classic Chimney Wall Hoods w/Recirculating Kit) Remove damper and discard with transition. Turn recirculating unit upside down. Place vent hood Flip hood over. Insert 6” of electrical wiring through the CAUTION: Secure vent hood. Make sure mounting upside down on recirculating unit.
  • Page 23: Installation (Dcwh/Dcwn/Dcwl Classic Chimney & Dtwn Tall Traditional Wall Hoods)

    To install ventillation kit refer to ventillation kit installation instructions. Slide spacer front over front lip. Push spacer rear up, Slide filter front over front lip. Push filter rear up, then Slide filter front over front lip. Push filter rear up, then then slide back over rear lip.
  • Page 24: Duct Cover Option (Dtwn Tall Traditional Wall Hoods)

    Place duct cover top inside duct cover base and lower until Slide duct cover in place and fasten from inside canopy Insert 6” of electrical wiring through the top of vent hood CAUTION: Using screws provided, secure vent hood to wall. desired height is found.
  • Page 25: Duct Cover Option (Dtws Slim Traditional Wall Hoods)

    Slide filter front over front lip. Push filter rear up, then Slide spacer front over front lip. Push spacer rear up, Place duct cover top inside duct cover base and lower until Slide duct cover in place and fasten from inside canopy slide back over rear lip.
  • Page 26: Installation (Dcih Classic Chimney Island Hoods)

    Installation (DCIH Classic Chimney Island Hoods) Run duct work down to bottom edge of duct Attach canopy to duct cover/soffit. From inside of Check framing where cutout will be. Cut appropriate size hole in ceiling. Either 7” or 10” cover/soffit and secure in place. Make sure the duct hood, seal top of hood to duct with aluminum tape.
  • Page 27: Service & Registration

    Service & Registration Service & Parts Only authorized replacement parts may be used in performing service on the appliance. Do not repair or replace any part of the appliance unless specifically recommended in the manual. All other servicing should be referred to a qualified technician.