Manager
The UNSET operation unsets the alarm. This menu option is only presented on the keypad after an alarm has been
activated and a valid user code has been entered.
Restore
Standard
Manager
The RESTORE operation restores an alert condition on the system and clears the alert message associated with that alert
condition.
An alert condition can only be restored after the zone(s) or fault(s) that triggered the alert condition have been restored
to their normal operating state and the RESTORE option in user programming is selected for that zone.
Isolate
Standard*
Manager
Isolating a zone deactivates that zone until such time as the zone is de-isolated. All zone types on the SPC can be
isolated.
Use of this feature to deactivate faulty or open zones should be considered carefully; once a zone is isolated, it is ignored
by the system and could be overlooked when setting the system in the future, compromising the security of the premises.
Inhibit
Standard
Manager
Inhibiting a zone deactivates that zone for one alarm set period. Only alarm, entry/exit, fire exit and line zone types can
be inhibited.
This is the preferred method of deactivating a faulty or open zone as the fault or open condition is displayed on the
keypad each time the system is being set to remind the user to attend to that zone.
Change code
Standard
Manager
This menu option allows users to change their user codes .
Engineer
Manager
This option allows users to grant access to manufacturer and engineer programming.
Set Date / Time
Standard
Manager
Use this menu option to program the time and date on the system .
Ensure the time and date information is accurate; these fields are presented in the event log when reporting system
events.
Test
Standard
Manager
This menu option provides the following test features:
1. Bell test : The bell test activates the external bells, strobe, internal bells, and buzzer in turn for 5 seconds to ensure
their correct operation.
2. Walk test: A walk test allows for testing of the operation of all alarm sensors on a system.
When this option is selected, the keypad displays the number of zones to test on the system. Activate each alarm sensor
(by opening the door or window) and check for an audible beep at the keypad. Isolated and inhibited zones are not
included in the walk test.
3. Audible Options: This option allows users to select which devices will activate during the walk test and which will be
silent.
View Log
Standard