Download Print this page

Kenmore 119.1643301 Use & Care Manual page 21

Liquid propane gas grill

Advertisement

Flow
Limiting
Valves
on LP Gas Tanks
Check
all connections
for LP Gas Leaks
Your
LP gas
tank
is equipped
with
a flow
limiting
valve
that
will
restrict
the
flow
of gas
due to a
sudden
change
in pressure.
This
can
often
activate
without
your
knowledge.
You
will
notice
among
other
things
that
your
grill
does
not get
as hot
as it should,
will
take
longer
to heat
up,
or you
may
not be able
to
light
all burners.
If you
notice
any
of the
above,
then
you
should
reset
the
valve
and
clear
your
gas
line.
To do
i.
2.
3.
4.
5.
6.
7.
8.
9.
this
Ensure
the
LP gas
tank
valve
is OFF.
Disconnect
the
regulator
from
the
LP gas
tank.
Open
all burner
control
knobs
including
the
side
burner
to Hi at the
same
time.
Close
all burner
control
knobs
to OFF.
Let the
LP gas
tank
stand
for
at least
10
minutes.
Reconnect
the
regulator
assembly
to the
LP
gas
tank.
Slowly,
meaning
about
1/4
turn
at a time,
turn
on the
LP gas valve.
Follow
the
burner
lighting
procedures
to light
the
burner
farthest
away
from
the
gas
source.
The
flow
limiting
valve
should
now
be reset.
This
flow
limiting
valve
is triggered
by sudden
changes
in pressure.
This
can
be caused
by a leak,
faulty
connection
of the
regulator
to the
LP gas tank,
turning
on the
LP gas tank
valve
too
quickly,
or
turning
the
burners
off by turning
the
LP gas
tank
valve
off before
turning
the
burner
control
knobs
to
off.
Note:
always
turn
off your
burners
using
the
burner
control
knobs
first
before
turning
the
LP gas
tank
valve
off.
Transportation
and
Storage
i.
Place
dust
cap
on the
cylinder
valve
outlet
whenever
the
cylinder
is not
in use.
Only
install
the type
of dust
cap
on the
cylinder
valve
outlet
that
is provided
with
the
cylinder
valve.
Other
types
of caps
or plugs
may
result
in leakage
of propane.
2.
Always
transport
your
cylinder
in an upright
position.
3.
Do not smoke
when
transporting
your
cylinder.
Never
test
for
leaks
with
a flame.
Prior
to
first
use,
at the
beginning
of each
season
or every
time
your
LP Gas tank
is changed
you
must
check
for
gas
leaks.
Follow
these
three
steps:
Make
a soap
solution
by mixing
one
part
liquid
detergent
and one
part
water
Turn the burner
control
knobs to the OFF position.
Then turn the gas ON at the source.
Apply
the
soap
solution
to all gas
connections
indicated
by the
arrows.
See diagram.
If
bubbles
appear
in the
soap
solution
the
connections
are
not
properly
sealed.
Check
each
fitting
and
tighten
or repair
as
necessary.
-_:,. Gas Valve
Manifold
QCC
Side Burner
Gas Valve
LP Gas Tank
If you
have
a gas
leak
that
cannot
be repaired
by tightening,
turn
off the
gas
at the
source,
disconnect
fuel
line from
your
grill
and
call
1-800-4-MY-HOME_
or your
gas
supplier
for
repair
assistance.
Disconnecting
A Liquid
Propane
Gas (LPG)
Tank
From Your
Grill
[]
Make
sure
the
burner
valves
and
LP gas
tank
valve
are
off.
(Turn
clockwise
to close.)
[]
Detach
the hose and regulator
assembly
from
the LP gas tank valve by turning
the quick
coupling
nut counterclockwise
21

Advertisement

loading

This manual is also suitable for:

119.16433010