Venting and programming the dispensing system
^ Refit the siphon into the new cleaning
agent container.
^ Press [.
The heating up phase will begin.
The programme control X will light
up red. The boiler and tank will fill up
with water, and the water will heat up.
Control X will light up green when
the filling and heating phase is
complete. The dishwasher is ready
for the new brand of cleaning agent.
^ Use the machine as normal.
Venting the rinsing agent
dispensing system
Before using the machine for the first
time, or if the container has not been
replenished on time or has been
allowed to empty, the rinsing agent
dispensing system must be vented. To
do this:
^ Remove the siphon from the rinsing
agent container (red).
^ Fill the container with rinsing agent,
or exchange the empty container for
a full one.
^ Insert the siphon tube into the
container and securely tighten it.
^ Switch the dishwasher off by
pressing [.
^ Press and hold controls X and Ä
together, and at the same time switch
on the dishwasher by pressing [.
^ Press and hold control X, and at the
same time press Ä twice in
succession.
P10 will show in the } display.
^ Press and hold control Ä until the
dispenser is vented - the dispenser
will then run more quietly.
^ Press [ to exit from input mode and
switch the dishwasher off.