Planning
controller / transmitter
REV23.03RF
Wall mounting of
controller / transmitter
REV23.03RF
Support of
REV23.03RF
Planning
Receiver
REV-R.03/1
Building Technologies
HVAC Products
Notes
• The room unit should be located in the main living room (on the wall or free-standing
using the support provided) while giving consideration to the following points:
• The distance to the receiver should not exceed 20 m or 2 floors
• The unit should be located such that the sensor is able to capture the room tempera-
ture as accurately as possible, without getting affected by direct solar radiation or
other heat or refrigeration sources (in the case of wall mounting, about 1.5 m above
the floor)
• The unit should be located such that it can transmit signals with as little interference
as possible. For this reason, the following points should be observed:
Do not mount the unit on metal surfaces
Not in the vicinity of electrical cables and equipment such as PCs, TV sets, mi-
crowave appliances, etc.
Not in the vicinity of large metal structures or construction elements with fine
metal meshes like special glass or special concrete
• The control mode can be changed via the menu-driven heating engineer settings.
• If the room temperature displayed does not agree with the room temperature effec-
tively measured, the temperature sensor should be recalibrated (refer to «Calibration
of sensors»).
• In the case of wall mounting, ensure that there is sufficient clearance for removing the
controller from its base, and for replacing it
First, fit the base. Then, engage the controller from the top. The base can be fitted to
most commercially available recessed conduit boxes or directly on the wall
• Refer to the Installation Instructions printed on the package.
• The receiver and switching unit should preferably be mounted near the controlled
device
• The unit should be located such that it can receive signals with as little interference
as possible. For this reason, the following points should be observed (same as with
the transmitter):
Not in control panels
Not on metal surfaces
Not in the vicinity of electrical cables and equipment such as PCs, TV sets, mi-
crowave appliances, etc.
Not in the vicinity of large metal structures or construction elements with fine
metal meshes like special glass or special concrete
• The location where the unit is mounted should be dry and free from splash water
• The unit can be fitted to most commercially available recessed conduit boxes or di-
rectly on the wall
Raumtemperaturregler REV23.03RF
min.
10 cm
9/17
CE1N2265en
22.02.2006