Lennox icomfort Quick Start Manual page 10

Residential communicating control system icomfort touch communicating thermostat
Hide thumbs Also See for icomfort:

Advertisement

FEATURES
INSTALLER SETTINGS
• Thermostat:
• Temp. Reading Calibration (-5 to 5°F, default is 0°F)
• Humidity Reading Calibration (-10 to 10°F, default is 0°F)
• System
• Equipment Name
• Filter 1 Timer Selection (Calendar or Run Time)
• Filter 2 Timer Selection (Calendar or Run Time)
• UV Bulb Timer Selection (Calendar or Run Time)
• Humidifier Pad Timer Selection (Calendar or Run Time)
• PureAir Timer Selection (Calendar or Run Time)
• Smooth Setback Recovery (Enabled/Disabled)
• Electric Heat Control Mode (Standard/EvenHeat)
• Gas Heat Control Mode (Staged/Modulating)
• Auto-Changeover Temp. Deadband (3 to 9°F,
default is 5°F)
• Max. Heat Setpoint (40 to 90°F, default is 90°F)
• Min. Cool Setpoint (60 to 99°F, default is 60°F)
• Heat Cool Stages Locked In (Enabled/Disabled)
• 1st Stage Differential (0.5 to 3°F, default is 0.5°F)
• 2nd Stage Differential (0.5 to 8°F, default is 1.5°F)
• 3rd Stage Differential (0.5 to 8°F, default is 2°F)
• 4th Stage Differential (0.5 to 8°F, default is 2.5°F)
• 5th Stage Differential (0.5 to 8°F, default is 3°F)
• 6th Stage Differential (0.5 to 8°F, default is 3.5°F)
• Staged Delay Timers (Enabled/Disabled)
• 2nd through 6th Stage Delays (5 to 120 min. in 5
min. increments, default is 20 min.)
• Locked in 2nd Stage HP by Outdoor Temp (off,
40°F, 45°F, 50°F, 55°F)
• Balance Point Control (enabled/disabled)
• Defrost Target Discharge Temp (50 to 60°F in 1°F
increments, default is 55°F)
• EvenHeater
Discharge Temp (80 to 130°F in 1°F
®
increments, default is 85°F)
• Dehumidification Control Mode (Display Ony, Basic,
Precision)
• Humidification Control Mode (Display Only,
Dewpoint Control)
• OK/Humid Boundary (45 to 60°F in 1°F increments,
default is 50°F
NOTE - Depending on type of system (conventional
heating/cooling or heat pump system) not all system
settings will be displayed.
icomfort™ Communicating Control System / Page 10
TESTS
A variety of system tests can be performed by the
installer. Press the tests tab, then press start to begin
system testing.
press start button below to begin system testing
start
setup
tests
select tests to run
TEST ALL
Blower
HP Heat − 1st
Stage
HP Heat − 2nd
Stage
Defrost Now
Cooling − 1st
Stage
Cooling − 2nd
Stage
alerts
TEST ALL is the default.
You can also test equipment individually. Use up / down
arrow buttons to select device.
Then press select, then start on the next screen to test
all or individual equipment.
setup
tests
select tests to run
TEST ALL
Blower
HP Heat − 1st
Stage
HP Heat − 2nd
Stage
Defrost Now
Cooling − 1st
Stage
Cooling − 2nd
Stage
alerts
The remove button allows to you remove individual
equipment from the TEST ALL list if you only want to test
certain equipment. Press the start button to begin testing.
CURRENT TEST: Blower
Check Blower Operation
When a test is running, a status screen will show
which test is being run. A Testing Process is Finished
confirmation screen will appear when testing is complete.
NOTE - The tests feature is not available until after setup
has been completed at least once.
equipment
HELP
selected tests
select
skip tests
diagnostics
EXIT
equipment
HELP
selected tests
TEST ALL
select
remove
start
diagnostics
EXIT
cancel
next