Scantronic 4601 Installation And User Manual page 6

Table of Contents

Advertisement

Engineering Program Commands
Zone 1
Entry/Exit zone/part set/auto restore (PIR)
Zone 2
Part set/entry route zone/auto restore (PIR, VIPER)
Zone 3
Part set/entry route zone/auto restore (PIR, VIPER)
Zone 4
Auto restore (PIR, VIPER)
Zone 5
Auto restore (PIR, VIPER)
Zone 6
Nothing selected (i.e., full set only door contact)
Zone 7
PA/auto restore (Pendant or hand-held PA)
Zone 8
Fire/auto restore
All other defaults are shown in the Engineer Program Command list by a ' '.
Engineering Program Commands
To change:
Engineer Access Code
Consecutive Code Jamming 32
Instant Night Mode
Remote Set
First Zone Lockout
Part Set Exit Timer
Bell Duration Timer
Entry Timer
Full Set Exit Timer
6 of 12
Key in: Then:
Notes
20
nnnn
See note 1
ENTER
ENTER
Any*
See note 2
ENTER
ENTER
33
Any*
See note 3
ENTER
ENTER
34
Any*
Zone 8 LED shows status
ENTER
ENTER
35
Any*
See note 4
ENTER
ENTER
41
1
= 10 seconds
ENTER
ENTER
2
= 20 seconds
ENTER
3
= 40 seconds
ENTER
4
= 60 seconds
ENTER
5
= Continuous
ENTER
6
= Instant (1.5s bleep
ENTER
followed by 20s silent)
42
1
= 1.5 mins
ENTER
ENTER
2
= 3 minutes
ENTER
3
= 5 minutes
ENTER
4
= 10 minutes
ENTER
5
= 15 minutes
ENTER
6
= 20 minutes
ENTER
7
= Continuous
ENTER
8
= 10s (for testing only)
ENTER
43
1
= 10 seconds (see note 5)
ENTER
ENTER
2
= 20 seconds
ENTER
3
= 40 seconds
ENTER
4
= 60 seconds
ENTER
44
1
= 10 seconds
ENTER
ENTER
2
= 20 seconds
ENTER
3
= 40 seconds
ENTER
4
= 60 seconds
ENTER
5
= Continuous
ENTER
6
= Final door or 60 seconds
ENTER
496368 Issue 1
4600
Default
7890
ON
OFF
ON
ON

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

460246034604460546084609 ... Show all

Table of Contents