Download Print this page
Scantronic 4603 Installation And Programming Manual
Scantronic 4603 Installation And Programming Manual

Scantronic 4603 Installation And Programming Manual

Programmable multifunction transmitter
Hide thumbs Also See for 4603:

Advertisement

Quick Links

4603
Programmable Multi-
Function Transmitter

Advertisement

loading

Summary of Contents for Scantronic 4603

  • Page 1 4603 Programmable Multi- Function Transmitter...
  • Page 2 Every effort has been made to ensure that the contents of this book are correct. However, neither the authors nor Scantronic accept any liability for loss or damage caused or alleged to be caused directly or indirectly by this book. The contents of this book are subject to change without notice.
  • Page 3: Physical Details

    The unit consists of a single-sided, SMT technology PCB, 90mm x 63mm, which incorporates a standard 4600 series encoder and a Scantronic 04689UK-50 transmitter. There are three types of input terminals, each with a positive (+ ve), Ground (Gnd) and an input connection (A,B,C) for convenience.
  • Page 4: General Data

    GENERAL DATA Some background data on the 4600 series signalling format will help you understand the more complex functions. The code sent by the transmitter is a 12 bit data frame repeated for approximately 1.5 seconds. To indicate a low battery, the transmission time is extended to approx.
  • Page 5 If a connection is made from input A to Gnd, the transmitter will send 12 site/unit code bits read directly from the DIL switches. No transmission will occur when the connection is removed. Single Channel, 'A' Input, bi-directional to trigger ('A' Inverted) for 4611, 4612, 4613, 4618/9, &...
  • Page 6 Two channel with bi-directional trigger on both A & B inputs. 4612, 4618/9 & 4660/75. 'MODE 0' DIL switch ON. 'MODE 1' DIL switch OFF. Input C linked to +ve. Connect as 4 except that the loop on input B is from Gnd to input B.) Two channel with bi-directional trigger only on B input.
  • Page 7 memory is turned 'ON' by pressing button C and 'OFF' by pressing button D. The new transmission will only occur if either memory has changed since the last transmission. If buttons B & D are replaced by two diodes and one button (B), the option functions as a nursecall with button B being the cancel button.
  • Page 8: Specifications

    4 years in FAST mode (50 triggers/day) (At least 10 years in storage with battery switched off.) Transmitter power: 1mW into 50 ohms. Typical free-space ranges using Scantronic 4618 receiver. At least 300m, using spring mini-helical (supplied). At least 600m, using small Yagi.
  • Page 9 0 and link 2 on 2 I/PB Note: It is not possible to wire the PIR Tamper Switch through the pins KEYSWITCH provided, as it will not work to the 4603-50/60 (CON) Transmitter correctly. Note: N/O to Set Part No. 495940 Issue 2...
  • Page 10 Tel: +33 (0)1 49 76 00 71 FAX: ++1 209 941 0806 Fax: +33 (0)1 49 76 00 58 MANUFACTURED IN THE UK BY SCANTRONIC LTD. PRODUCT SUPPORT (UK) - TEL - (0891) 616343 BETWEEN 09:00 AND 17:30, MONDAY TO FRIDAY.