Technical Specification - Scantronic 4601 Installation And User Manual

Table of Contents

Advertisement

The 4600 electronic intruder alarm system is a fully programmable, 8-zone,
bells only, radio security system, designed for domestic installations and to
comply with BS 6799, Class 3.
The system comprises a main control panel, which is hard-wired to an
external bell/strobe, together with detector/transmitters, which are wire-free
and communicate with the main control panel by means of radio signals.

Technical Specification

Electrical
Input supply voltage
Short-circuit protection
Reverse polarity protection = Battery connections are reverse polarity
Battery back-up
Auxiliary output
Dimensions
Weight
Humidity
Operating temp.
2 of 12
Introduction
= 225-253VAC, 50Hz, Max 30VA.
= Outputs short-circuit protected for indefinite
periods by means of Polyswitches which will
recover after removal of short-circuit.
protected for at least 5 minutes.
= Back-up time, panel only with fully charged
battery, typically 20 hours 12V Lead Acid
battery, typically 2.1AH. Float charge voltage
13.7V typically. Charge time for flat battery,
maximum 14 hours, typically 6 hours.
= 13.7VDC. Continuous current available
200mA. Maximum short term current 1A for
up to 20 minutes.
= h x w x d 160 x 257 x 72 mm.
= 1.2 kg.
= 80° RH.
= -10° to + 55° C
496368 Issue 1
4600

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

460246034604460546084609 ... Show all