Top Vent - Vertical Termination - (continued)
No Elbow
Figure 7.7
28
Note: The vertical termination baffl e should be used for runs of 10 feet (3,05
m)or greater.
The vertical restrictor has a break away portion that creates a larger hole. If
venting 10-18 feet (3,05 m - 5,49 m), the break away portion MUST be removed
and the larger hole must be used. If venting over 18 feet (5,49 m), the break
away portion should be left in place and the small hole should be used.
V
1
Heat & Glo • SOHO-B-CEB, SOHO-N-CEB, SOHO-P-CEB • 2111-980 Rev. F • 8/11
V
= 38 ft. Max. (11.58 m)
1
V
= 3 ft. Min. (91,4 cm)
1
VERTICAL TERMINATION BAFFLE
BREAK AWAY PORTION