Supply connection HMI device
Rated voltage
Valid range
Transients, maximum permissible
Time between two transients, minimum
Fuse, internal
Current consumption
Supply connection fan
Rated voltage
Valid range
Current consumption
Fans
Service life L10/MTBF [h]
MP 377 15" Touch daylight readable (WinCC flexible)
Operating Instructions (Compact), 04/2009, A5E02532357-01
Typical
Constant current, maximum
Power on current surge I
2
Constant current, typical
Inrush current
+24 V DC
19.2 V to 28.8 V (–20 %, +20 %)
35 V, 500 ms
50 s
Electronic
approx. 1 500 mA
Approx. 2 800 mA
t
Approx. 5.0 A
+24 VDC
19.2 V to 28.8 V (–20 %, +20 %)
For the two fans in sum.
Approx. 50 mA
Approx. 200 mA
95000/280000 @20°C