BD-Fly – Programming Guide SUMMA RY SUMMARY INTRODUCTION GENERAL CONFIGURATION 1.1. ENERAL DEFAULT SETTINGS 1.2. ARACODA ADVANCED FEATURES 1.2.1. WITCH ON DELAY 1.2.2. HUTDOWN TIMERS 1.2.3. O DATA LOSS MODE AND ARACODA EADER 1.3. EADING 1.4. PERATING 1.4.1. IME MODE 1.4.2.
Page 3
BD-Fly – Programming Guide 5.4. CCEPTED CHARACTERS 5.5. 39 C HECK IGIT ERIFICATION 5.6. ET LENGTHS FOR 3.9/ CODE 93 SETTINGS 6.1. NABLE ISABLE 6.2. ENGTHS FOR CODE 128 SETTINGS 7.1. 128/EAN 128 NABLE ISABLE 7.2. 128/EAN 128 ET LENGTS DOR 7.3.
BD-Fly – Programming Guide Intro duction The Baracoda D-Fly scanners can be programmed by scanning barcode labels which contain commands for the decoder. Programming labels must be Code128, with specific starting and ending characters. These labels will always be read, even if Code128 symbology is disabled.
BD-Fly – Programming Guide Gen eral Configuration 1.1. Gen eral default settings The reading of the "Reset to factory settings” label turns all the parameters of the scanner back to default settings and switches it off. Reset to factory settings June 07...
1. 2. 1. Sw it ch on de lay In order to switch on the D-Fly in its standard mode, you should just press the trigger. You can set up the scanner to be switched on only after keeping the trigger pressed for two (2) seconds by reading the appropriate barcode.
1. 2.3 . No dat a lo ss m o de an d B araco da H e ade r Baracoda header: It is a proprietary data encapsulation. It is necessary to activate it to use the Baracoda keyboard emulation (Kemul) and Terminal.
Pressing it the first time will switch on the beam but will not switch on the decoder (thus allowing user to aim at the correct barcode) while pressing the trigger the second time will activate the decoder thus allowing the D-Fly to actually decode the barcode. Trigger (*)
(See part 1.3.3.) 1. 4. 1. Re al Tim e m o de Erases all codes in memory and forces the D-Fly in Real time mode. No other setting is changed. Enable 1. 4.2 . Re al Tim e m o de w ith “No dat a loss mo de”...
BD-Fly – Programming Guide 1.5. Buzzer an d Led Settings You can use these options to enable or disable the buzzer and / or the Led. LED ON (*) LED OFF Good read beep on (*) Good read beep off ACK beep on (*) ACK beep off Beep level volume = HIGH (*)
BD-Fly – Programming Guide 1.6. Bluetooth comman ds 1. 6. 1. Blu etooth n am e You can change the scanner Bluetooth name; name that you see during a search of Bluetooth peripheral. Programming procedure for “Set Bluetooth Name” Set BT Name End of config June 07...
BD-Fly – Programming Guide 1. 6.2 . Sniff pe rio d set tin gs Change the Sniff period. If the higher is the latency and the smaller is the power consumption. Default value is 150ms. Sniff period = 150ms (*) Sniff period = 100ms Sniff period = 200ms Sniff period = 300ms...
BD-Fly – Programming Guide 1. 6.3 . Se cu rity (co de PIN ) sett in gs Some Bluetooth device will not accept connections with devices that do not have a security code. Disable BT security code Enable BT security code (*) June 07...
BD-Fly – Programming Guide 1.7. Prefix and suffix The barcode string can be added a prefix and/or a suffix. The symbology prefix/suffix can be added by Baracoda Manager only. These can come as described below: General_Prefix Symbology_Prefix Barcode Symbology_Prefix General_Suffix 1.
Page 15
BD-Fly – Programming Guide *= max length of the Suffix (Prefix) is 32 characters Set prefix Set suffix End of configuration June 07...
BD-Fly – Programming Guide 1.8. Set min or Max length option 1. 8. 1. S che m a The following is a procedure to follow for every barcode symbology. June 07...
BD-Fly – Programming Guide 1. 8.2 . Sy m bolo gy t able Selected Header Selected Header Symbology Symbology SELECT ALL Interleaved 2 of 5 Standard 2 of 5 Code 93 (industrial 2 of 5) Code 128 / EAN Code 11 Code 39 Codabar Start –...
BD-Fly – Programming Guide 1.9. Sym bology Identifier AIM Identifier will be transmitted at the beginning of the barcode. More information about the AIM Identifier available in Appendix2 Symbology identifier - AIM - not transmitted (*) Symbology identifier - AIM - transmitted 1.10.
BD-Fly – Programming Guide 1.11. Set deco der barcode length You can set a fixed length for the barcode decoding. The scanner will only decode barcodes of this length. Set barcode length END of config June 07...
Sets the defaults decoder settings for all the symbologies Set Decoder Default Settings 2.2. Enable/Disable All Symbolgy Even if all symbologies are disabled, the D-Fly will always be able to read the programming barcodes of this document. Disable all symbologies Enable all symbologies (*)
BD-Fly – Programming Guide Codabar 3.1. Enable/Disable Co dabar To enable or disable Codabar, scan the appropriate barcode below Disable Enable (*) 3.2. Codabar Start/ Sto p charac ters Not transmitted (*) Transmitted June 07...
BD-Fly – Programming Guide 3.3. Codabar Chec k Digit Verific ation (AIM recommendation) Not used (*) Checked and transmitted Checked but not transmitted 3.4. Set Len gth s for Codabar Any length Barcode length Min=6 (*) June 07...
BD-Fly – Programming Guide Code 11 Settin gs 4.1. Enable/Disable Co de 11 To enable or disable Code 11, scan the appropriate barcode below. Code 11 - not active (*) \ S O Code 11 - active 4.2. Code 11 chec k digit(s) verification 1 digit (*) 2 digits June 07...
BD-Fly – Programming Guide 4.3. Transmit Co de 11 ch eck digit(s) This feature selects whether or not to transmit the Code 11 check digit(s). Check and transmitted (Enable) (*) Check but not transmitted (Disable) 4.4. Set Len gth for Code 11 This features check the length of the barcode Code 11 - barcode length - any length Code 11 –...
BD-Fly – Programming Guide Code 39 settings 5.1. Enable/Disable Co de 39 To enable or disable Code 39, scan the appropriate barcode below Enable (*) \ V T \ V T \ F N C 4 \ N U L \ E O T E D \ S O H A \ F F \ F F Disable 5.2.
BD-Fly – Programming Guide 3.9/ Co de 93 Settings 6.1. Enable/Disable Co de 93 To enable or disable Code 93, scan the appropriate barcode below Code 93 - not active Code 93 – active (*) 6.2. Set Len gth s for Code 93 Code 93 - barcode length - any length Code 93 - barcode length - minimum length = 6 (*) June 07...
BD-Fly – Programming Guide 7.3. EAN 128: Group Separator ‘FNC1’ included in an EAN128 code is transmitted by default as ‘GS’ (Group Separator – 0x1D). Enable GS transmission (*) Disable GS Transmission Define GS End of configuration June 07...
BD-Fly – Programming Guide The common request to replace ‘GS’ by the | (pipe) can be done through the scan of : Define | as GS Even if the “AIM ID transmit” is disabled, it is possible to enable the AIM ID transmission for EAN128. 7.4.
BD-Fly – Programming Guide Interleaved 2 of 5 Settings 8.1. Enable/Disable Interleaved 2 of 5 To enable or disable Interleaved 2 of 5, scan the appropriate barcode below Interleaved 2 of 5 - not active Interleaved 2 of 5 – active (*) 8.2.
BD-Fly – Programming Guide MSI Co de Settings 9.1. Enable/Disable MSI To enable or disable MSI code, scan the appropriate barcode below MSI Code - not active (*) MSI Code – active 9.2. MSI Ch eck D igit Verification and Transmit MSI Code - check digit - mod 10 - checked and transmitted (*) MSI Code - check digit - mod 10 - checked but not transmitted MSI Code - check digit - double mod 10 - checked and transmitted...
BD-Fly – Programming Guide Stan dard 2 of 5 Settings 10. 1. Enable/Disable Standar d 2 of 5 To enable or disable Standard 2 of 5 code, scan the appropriate barcode below Standard 2 of 5 - not active \ V T \ V T \ F N C 4 \ N U L \ E O T H D \ S O H B \ F F \ F F Standard 2 of 5 –...
BD-Fly – Programming Guide 10. 3. Set lengths for Standard 2 o f 5 Standard 2 of 5 - barcode length - any length Standard 2 of 5 - barcode length - minimum length = 6 (*) June 07...
BD-Fly – Programming Guide 11. 2. Transmit E AN13 Ch eck Digit UPC / EAN - check digit - UPC-A and EAN13 - transmitted (*) Enab l e EAN13/UPCA c hecks um t r ans m i s s i on \ V T \ V T \ F N C 4 ~ \ N U L \ E O T D D \ S O H G \ F F \ F F UPC / EAN - check digit - UPC-A/EAN 13 - not transmitted 11.
BD-Fly – Programming Guide Control Characters: Name Programming label June 07...
Page 47
BD-Fly – Programming Guide APPENDIX 2 The SI prefix is a two (2) or three (3) character string: ] c m where ] : SI indicator c : Symbology Identification m : Modifier characters (optional) Symbology Character Code 39 Telepen Code 128 Code One EAN/UPC...
Need help?
Do you have a question about the D-Fly and is the answer not in the manual?
Questions and answers