Pentair AQ Series Instruction Manual
Pentair AQ Series Instruction Manual

Pentair AQ Series Instruction Manual

Electronic control pump

Advertisement

Quick Links

AQ Series
Electronic Control Pump
Instruction Manual
ISO 9001 Certified

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AQ Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pentair AQ Series

  • Page 1 AQ Series Electronic Control Pump Instruction Manual ISO 9001 Certified...
  • Page 2: Ec Declaration Of Conformity

    EC Declaration of Conformity Pentair Southern Cross declares that the machinery described: Name : Water Pump Model : AQ Series Conform to the following directive: 2006/42/EC—Machinery directive 2006/95/EC—Low voltage directive 2004/108/EC—EMC (Electromagnetic compatibility) directive Refer to the following standards: EN ISO 12100-1:2003...
  • Page 3: Installation

    (refer to by the warranty. 1. Introduction 2. Automatic Pump Control 1.1 Applications: The AQ series pumps are designed for water supply ELECTRONIC CONTROL PUMP and pressure boosting in residential, commercial and light industrial applications where low or Power inadequate water pressure exists.
  • Page 4: Wiring Diagram

    5. Wiring diagram 3. Outdoor: When the pump is installed outside, please provide a suitable cover to protect it from WARNING: all weather conditions. Please do not allow Risk of Electric Shock - This pump is supplied with any foreign objects fall into the motor fan cover. a grounding conductor and grounding-type attachment plug.
  • Page 5: Pressure Switch

    8. Pressure switch 3. For intitial startup or after long periods of inactivity, place a screwdrive against the shaft at Adjust the pressure switch setting as shown in Fig 7. the motor end and turn clockwise to see if rotor Make sure the system is primed.
  • Page 6 10. Frequently asked questions: 11. Dimensions: (mm) 1. What is the maximum pressure switch activation point? Adjust the pressure only when the cut in pressure Outlet is higher than the preset activation point. Do not adjust the pressure to exceed the maximum pressure range (refer to speci cation) because the Inlet pump will not stop if teh pressure is above the...
  • Page 7: 13. Troubleshooting

    13. Troubleshooting Before starting troubleshooting the pump, make sure that the power has been Cause Problem Remedy a. Water leakage higher than 3 lpm. Check the system,the tap,etc, and 1. Pump doesn't stop: b. Manual start switch (RESET) is 1. Press it for several times. blocked.
  • Page 8 A division of Pentair Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690 Phone: 131 PUMP Web: www.southerncross.pentair.com...