CONTENTS GENERAL Table of contents............Preface, Ez Troubleshooting........Cloning Mode............How to fix the scanner to the terminal....... How to change a cable..........How to set up the parameter........SETTING GROUP(GROUP1~14) Interfaces selection, Computer type, Default, Setup Code ON/OFF..........Reading Mode ............Wireless Scanner Setting........
CLONING MODE WHAT IS CLONING MODE? CLONING duplicates a scanners settings in other scanners. It can save time when a number of scanners must be programmed to the same settings. HOW SHOULD CLONING WORK? 1. Using this guide, make all the necessary settings for one wand. 2.
Page 5
EXAMPLE : 1. PROJECT ASSIGNMENTS: 1.1. Beep tone: BEEP LOW -- HIGH. 1.2. Capslock Mode: CAPSLOCK ON. 1.3. Reading Mode: CONTINUOUS AUTO OFF. 2. SETTING PROCEDURE: 2.1. Scan BEEP LOW -- HIGH (GROUP 3)(page13). 2.2. Scan CAPSLOCK ON (GROUP 11). 2.3.
HOW TO CONNECT THE SCANNER TO THE HOST TERMINAL: Handheld Barcode Scanner KEYBOARD WEDGE INTERFACE 1. Power down the host computer. 2. Disconnect the keyboard cable from the computer. 3. Connect the “Y ” cable between the keyboard and the scanner and computer. 4.
USB INTERFACE The USB Interface supported is compatible with Apple MAC series, later PCs and Windows 98, 2000, Me and XP, Vista. 1. Connect the USB cable between the scanner and the computer. 2. The scanner will beep. 3. The scanner will detect the USB driver automatically. (The first time the scanner is connected via the USB port, follow the appropriate instructions for the host computer.) 4.
HOW TO SET PARAMETERS How do you program a scanner with this user’s guide? 1. Use the scanner to scan at the bar code representing the function/ parameter you want to set. 2. When you hear two beeps, the new settings have been defined or updated into the memory processor.
GROUP-1 INTERFACES SELECTION, COMPUTER TYPE, DEFAULT, SETUP CODE . A001$ DEFAULT . C004$ PC-AT COMPUTER TYPE . C007$ NOTEBOOK* SYMPTOMS SOLUTION Scanner seems to be 1. Unplug the cable from the host computer. performing as usual, 2. Plug the cable back into the host computer. but no data is being 3.
GROUP-2 READING MODE SETTING . F005$ LED is always on. The trigger does not function in Continuous Mode. CONTINUOUS MODE . F001$ The LED is on steady if a bar code is close to the scanner, but starts flashing if no bar code is detected after 60 seconds.
APPENDIX WIRELESS SCANNER SETTINGS POWER OFF TIMEOUT The timeout before automatic power-off to save battery power. . B017$ 1 MIN . B018$ 3 MIN . B019$ 5 MIN . B020$ 10 MIN . B021$ DIABLE (NO POWER-OFF) LED & BEEPER INDICATION Status Blue/Green LED Red LED...
Page 12
APPENDIX WIRELESS SCANNER SETTINGS SMARTPHONE CONNECTION Android 1. Pair with the scanner via [BT mode - SPP]. 2. Install Bluetooth Connect.apk and enter the program. 3. Enable [BluetoothConnect] in the Language & Keyboard setting window and choose [BluetoothConnect] as Input Method.
GROUP-5 ACCURACY ADJUSTMENT . A010$ ACCURACY ADJUSTMENT Accuracy Adjustment assures a more reliable decoded output. Enabling the feature and setting a number from 1 to 9 subjects the decoded output a higher standard of accuracy. The higher the number, the greater the accuracy. SETTING PROCEDURE: 1.
GROUP-6 LABEL TYPE POSITIVE / NEGATIVE, ENABLE AND DISABLE CODE ID LABEL TYPE POSITIVE / NEGATIVE .D021$ DISABLE NEGATIVE LABEL [POSITIVE LABEL ENABLE] .D022$ ENABLE NEGATIVE LABEL [POSITIVE & NEGATIVE ENABLE] ENABLE CODE ID .A008$ FACTORY ID ON .A014$ AIM ID ON .A015$ SET ID ON DISABLE CODE ID...
GROUP-8 CODE ID CONFIGURATION: SET ID . P001$ EAN 13 Set ID . P002$ EAN 8 Set ID . P003$ UPC E Set ID . P004$ UPC A Set ID . P005$ Code 39 Set ID . P013$ Code 93 Set ID .
Page 20
GROUP-9 CODE ID CONFIGURATION: SET ID . P014$ MSI Code Set ID . P015$ UK Plessey Set ID . P017$ Matrix 2 of 5 Set ID . P006$ Interleaved 2 of 5 Set ID . P018$ Industrial 2 of 5 Set ID .
GROUP-14 WAND EMULATION PARAMETER SETTING . D001$ LEVEL DURATION OF MINI WIDTH 200us . D002$ 600uS . D003$ POLARITY OF IDLE CONDITION . D004$ HIGH . D005$ OUTPUT OF WAND EMULATION Bar High / Space Low . D006$ Bar Low / Space High .
Page 29
APPENDIX FULL ASCII ( Code 39 ) NUMERIC TABLE SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters.
GROUP-18 SYMBOLOGIES: MSI CODE, UK PLESSEY CODE . L001$ . L008$ ENABLE CHECK DIGIT DOUBLE 11 . L002$ PLUS MOD 10 . L009$ DISABLE CHECK DIGIT SINGLE . L004$ MOD 10 . L005$ CDV & SEND CD MIN LENGTH [ 6 ] .
Page 31
APPENDIX FULL ASCII ( Code 39 ) NUMERIC TABLE SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters.
Page 33
APPENDIX FULL ASCII ( Code 39 ) NUMERIC TABLE SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters.
GROUP-20 SYMBOLOGIES: INTERLEAVED 2 OF 5, CODE 11 . J001$ INTERLEAVED 2 OF 5 . J008$ ENABLE . J002$ First digit suppressed . J009$ DISABLE . J003$ Last digit suppressed . J014$ DISABLE CDV . J004$ NO suppressed . J006$ CDV &...
Page 35
APPENDIX FULL ASCII ( Code 39 ) NUMERIC TABLE SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters.
GROUP-21 SYMBOLOGIES: INDUSTRIAL 2 OF 5, MATRIX 2 OF 5 INDUSTRIAL 2 OF 5 . N001$ . N005$ ENABLE . N002$ CDV & NOT SEND CD DISABLE . N006$ . N003$ MIN LENGTH [ 6 ] DISABLE CDV . N007$ .
Page 37
APPENDIX FULL ASCII ( Code 39 ) NUMERIC TABLE SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters.
GROUP-22 SYMBOLOGIES: CODABAR . I 001$ CODABAR ENABLE . I 007$ . I 002$ CDV & NOT SEND CD . I 008$ DISABLE . I 005$ MIN LENGTH [ 6 ] . I 009$ DISABLE CDV . I 006$ MAX LENGTH [ 48 ] CDV &...
Page 39
APPENDIX FULL ASCII ( Code 39 ) NUMERIC TABLE SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters.
GROUP-23 SYMBOLOGIES: ABC- CODABAR, CX- CODABAR . I 017$ ABC- CODABAR . I 039$ . I 018$ INSERT DATA- ON . I 036$ . I 035$ INSERT DATA- OFF SET INSERT DATA* The data can be any alphanumerics of FULL ASCII Table (GROUP 33-41)(page 51-59) ABC-CODABAR (American Blood Commission).
GROUP-24 SYMBOLOGIES: CODABAR COUPLING, ADJACENT REQUIRED CODABAR COUPLING . I 019$ . I 041$ . I 020$ INSERT DATA - ON . I 026$ . I 021$ INSERT DATA - OFF SET INSERT DATA* ABC-Codabar and CX-Codabar have certain rules regarding the Stop Character of first bar code and the stop character of second bar code while in conjunction, while Codabar- Coupling is enabled, the data from any two Codabar bar codes...
GROUP-25 SYMBOLOGIES: STANDARD & FULL ASCII CODE 39, CODE 32 STANDARD CODE 39 . G003$ & FULL ASCII 39 DISABLE CDV . G008$ . G004$ ENABLE . G009$ CDV & SEND CD . G005$ DISABLE . G001$ CDV & NOT SEND CD .
Page 43
APPENDIX FULL ASCII ( Code 39 ) NUMERIC TABLE SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters.
GROUP-27 SYMBOLOGIES: UPC-E SYSTEM NUMBER . H064$ UPC-E0 E [ 0 ] OFF . H063$ E ( 0 ) ON . H065$ UPC-E1 E [ 1 ] ON . H066$ E ( 1 ) OFF NOTE: Most UPC bar codes lead with 0 number systems, for these bar codes use UPC E(0) selection.
GROUP-31 SYMBOLOGIES: EAN/UCC-128, CODE 128 . M001$ EAN/ UCC-128 . M005$ ENABLE . M002$ FUNC 1 CHAR SEND . M006$ DISABLE . M003$ FUNC 1 CHAR NOT SEND . M007$ CODE ID ENABLE . M004$ DEFINE EAN 128 CODE ID DISABLE NOTES: DEFINE EAN 128 The first FNC1 character is translated to ]c1, and the second FNC1 character is translated to an ASCII <GS>...
GROUP-45 TROUBLE SHOOTING Our Barcode Scanners are simple to install and use. Most operational issues can be attributed to: INCORRECT INTERFACE CONNECTION INCORRECT CONFIGURATION SETUP POOR BARCODE QUALITY GENERAL PROCEDURES First, make sure the scanner is rmly connected to the host computer, when attached correctly, the scanner will emit one long beep.
Page 64
GROUP-46 TROUBLE SHOOTING RS232 INTERFACE PROBLEMS Once you read bar code, there is no output on the monitor, the symptoms may be caused by: 1. Have you set the protocol of RS232 like Baud rate, data bits, parity and handshaking etc. of a scanner to match to the PC terminal setting? Solution: reset the above mentioned RS232 protocol of scanner to match to PC protocol.
Page 65
GROUP-47 TROUBLE SHOOTING Is the proper symbology enabled? Each bar code symbology can be individually enabled or disabled. It is suggested that you enable only those that you will be scanning, thereby eliminating the possibility of mis reads from the scanning of other symbologies. Does the selected bar code symbology con guration match the bar code(s) being read? Scanned data from each bar code symbology can be restricted...
APPENDIX 2 Cable Pin Assignment INTERFACES: 1. TTL, Wand Emulation 1.1 ) AMP (D-Sub 9Pin): Signal Data +5VCC 1.2 ) Din 5 male (240 degree): Signal + 5VCC Data 2. Keyboard Interface: Type of connector: 2.1 ) PS/2 Mini Din6 Female: Signal PC Data +5VCC...
Page 70
Type of connector: 2.3) PC-AT: Din 5 Male: Signal KB-Clk KB-Data +5VCC 2.4) PC-AT: Din 5 Female: Signal PC-Clk PC-Data +5VCC 3.RS232 Interfaces: 3.1) DB9F Signal TXD(Out) RXD(In) CTS(In) RTS(Out) +5VCC 3.2) DB25F Signal RXD(In) TXD(Out) CTS(In) RTS(Out) +5VCC +5VCC...
APPENDIX 3 BAR CODE TEST CHART NARROW WIDE CHAR.GAP DENSITY mm[mil] mm[mil] mm[mil] RATIO MEDIUM 0.25(10) 0.625(25) 0.25(10) 1/2.5 DENSITY MEDIUM DENSITY NW-7 [CODABAR] CODE-39 Interleaved 2of5...
Page 72
APPENDIX 3 BAR CODE TEST CHART NARROW WIDE CHAR.GAP DENSITY mm[mil] mm[mil] mm[mil] RATIO 0.33(13) 0.825(32.5) 0.33(13) 1/2.5 DENSITY LOW DENSITY...