PCAN-Optoadapter – User Manual
The lines for the differential CAN signal CAN_H and CAN_L are
terminated on the adapter with a 120-Ω resistor (fixed). An
additional termination at the CAN interface is not needed.
2.2

Connection Secondary Side

A High-speed CAN bus (ISO 11898-2) is connected to the 9-pin D-
Sub connector. The pin assignment for CAN corresponds to the
specification CiA® 102.
Figure 3: Pin assignment at the secondary side (D-Sub male)