remove the knob and adjust the regulation screw, which
is positioned in or next to the tap pin, until the flame is
small but steady.
N.B.: in the case of liquid gas, the regulation screw
must be screwed in to the bottom.
check that the flame does not turn off when you turn
the tap quickly from high to low.
d Regulating the primary air of the burners:
The primary air of the burners requires no regulation.
Important
Table1 (For Hungary)
Burner
Fast (R)
Semi Fast (S)
Auxiliary (A)
Supply pressures
At 15°C and 1013 mbar-dry gas
P.C.I. G20
37,780 MJ/m
S S
A
R
K 342 M/EU
K 342 MS/EU
K 343 M/EU

Burner and Nozzle Specifications

G 20
By-pass
Thermal
1/100 (mm)
power kW
41
3,30
30
2,10
30
1,15
25 mbar
3
On completion of the operation, replace the old rating
sticker with one indicating the new type of gas used. This
sticker is available from our Service Centres.
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in
compliance with current National Regulations relative to
"regulators for channelled gas".
G 25.1
Nozzle
Thermal
1/100 (mm)
power kW
116
2,60
106
1,70
79
0,90
25 mbar
P.C.I. G30
P.C.I. G25.1
6
G 30
Nozzle
Thermal
1/100 (mm)
power kW
116
2,60
106
1,70
79
0,90
30 mbar
122,8 MJ/m
3
32,510 MJ/m
3
Nozzle
1/100 (mm)
86
70
50