ENGLISH
Charging the batteries with the battery charger
1.
(For WET batteries only) check the level of electrolyte inside the batteries. If necessary, top up through the caps (45).
Leave all the caps (45) open for battery charging.
When the correct level is reached, clean, if necessary, the upper surface of the batteries.
2.
Connect the battery charger cable (48) to the electrical mains.
WARNING!
Check that the voltage and frequency shown on the machine serial number plate (37) match the electrical
mains values.
NOTE
When the battery charger is connected to the electrical mains, all machine functions are automatically disabled.
3.
When the green warning light (50) turns on, the batteries are charged.
4.
For further information about the battery charger operation (47), see the Battery Charger Manual.
5.
Disconnect the battery charger cable (48) from the electrical mains and place it in its housing on the machine.
6.
(For WET batteries only) Close all the caps (45).
7.
Close the hood (7). The machine is ready to be used.

FUSE CHECK/REPLACEMENT/RESET

1.
Drive the machine on a level ground and engage the parking brake with the pedal (3) and the lever (4).
2.
Turn the ignition key (72) to "0".
3.
Open the hood (7).
4.
Disconnect the battery connector (46).
Lamellar fuse check/replacement
5.
Remove the fuse box cover (51).
6.
Check/replace the relevant fuse among the following (Fig. 19):
F1: Main fuse (key circuit) (15 A)
F2: Filter shaker motor fuse (25 A)
F3: Manual vacuum system fuse (40 A) (optional)
F4: Vacuum system motor fuse (30 A)
F5: Horn and pivoting light fuse (10 A)
F6: Working light fuse (10 A) (optional)
7.
Remove the electrical component box cover (55).
8.
Check/replace the following fuse (Fig. 20):
FT: Drive system fuse (70 A)
Circuit breaker check
9.
Check for deactivation of one of the following fuses, then reset it after the relevant motor has cooled down:
FA: Main broom motor circuit breaker (30 A) (52)
FB: Side broom motor circuit breaker (10 A) (53)
Assembly
10.
Assemble the components in the reverse order of disassembly.
F1 F2
F3
F4
24
USER MANUAL
F5
F6
F7
Figure 19
FLOORTEC R 570 B
F8
S311413
FT
Figure 20
146 2725 000(2)2007-02 A