superior fires PI27 WESTBURY GROVE BRASS NG F500379 Installation & User's Instructions

superior fires PI27 WESTBURY GROVE BRASS NG F500379 Installation & User's Instructions

Inset flueless gas fire

Advertisement

Quick Links

INSTALLATION & USER INSTRUCTIONS
Superior Fires
Christchurch, Dorset BH23 2BT
Tel: 01202 588 632
Fax: 01202 499326
www.superiorfires.co.uk
e : info@superiorfires.co.uk
Please note : Except where otherwise stated, all rights, includ-
ing copyright in the text, images and layout of this booklet is
owned by Superior fires Ltd You are not permitted to copy or
adapt any of the content without the prior written permission
of Superior fires Ltd.
INSET FLUELESS GAS FIRE
MODELS COVERED BY THESE INSTRUCTIONS
PI27 WESTBURY GROVE BRASS NG
PI27 WESTBURY GROVE CHROME NG
PI27 WESTBURY GROVE BLACK NG
PI27 WESTBURY ELEGANCE BRASS NG
PI27 WESTBURY ELEGANCE BRASS/BLK NG
PI27 WESTBURY ELEGANCE BLACK NG
PI27 POSITANO NG
PI27 WESTBURY GROVE BRASS LPG
PI27 WESTBURY GROVE CHROME LPG
PI27 WESTBURY GROVE BLACK LPG
PI27 WESTBURY ELEGANCE BRASS LPG
PI27 WESTBURY ELEGANCE BRASS/BLK LPG F500539
PI27 WESTBURY ELEGANCE BLACK LPG
PI27 POSITANO LPG
WESTBURY GROVE
POSI TANO
WESTBURY ELEGANCE
The products covered by this booklet are protected under
patent GB2275331C.
All instructions must be handed to the user for
Revision C - 03/13
1
F500379
F500380
F500534
F500536
F500538
F500540
BS EN 14829 : 2007
F500381
F500420
F500421
F500535
F500537
F500541
F500422
safekeeping.
©
2013 Superior Fires Ltd.
GB IE
KM579167

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PI27 WESTBURY GROVE BRASS NG F500379 and is the answer not in the manual?

Questions and answers

Summary of Contents for superior fires PI27 WESTBURY GROVE BRASS NG F500379

  • Page 1 All instructions must be handed to the user for owned by Superior fires Ltd You are not permitted to copy or safekeeping. adapt any of the content without the prior written permission of Superior fires Ltd.
  • Page 2: Table Of Contents

    • As with any gas fire, a fire guard complying with BS 8423 must be used in presence of pets, children, and the elderly or infirm. • Consult ALL instructions before installation and use of this appliance. This appliance is free from any asbestos material. © 2013 Superior Fires Ltd.
  • Page 3: Appliance Data

    It is not recommended, however that the appliance be installed in areas where it is likely to be exposed to per- sistent strong draughts, that may be generated by outside doors or windows, air vents etc. It is recommended that the appliance should not be installed within 1 metre of any air vent. © 2013 Superior Fires Ltd.
  • Page 4 The temperature rating of any surround used must be 150°C minimum. Clearances to the sides of the appliance are 100mm (4”). Clearance to the front of the appliance is 500mm (20”). © 2013 Superior Fires Ltd.
  • Page 5: Ventilation

    Coal Set (Front & Rear) (Westbury models) Rubber grommet Cable fixing kit Screw pack including wall plugs Positano screw pack consists of: No. 8 pozi self tapping screws Westbury screw pack consists of: No. 8 pozi self tapping screws © 2013 Superior Fires Ltd.
  • Page 6: Appliance Installation

    75mm air gap at the sides and rear and 100mm air gap above the firebox. Alternatively the firebox may be insulated with 75mm of fibre glass wool or rock wool to the sides, rear and 100 mm to the top. © 2013 Superior Fires Ltd.
  • Page 7 The hearth may now be put in place (If fitted). Again this should not bridge the cavity where it projects into the wall space. Finally install the fireplace or fire surround and back panel/marble to its finished location. © 2013 Superior Fires Ltd.
  • Page 8: Installation Method

    It is also a good idea to enable as much airflow as possible, into and out of the area behind the fire without causing excessive heat loss from the room when the fire is off. © 2013 Superior Fires Ltd.
  • Page 9: Installation Method

    Note: Surplus cable MUST NOT be cut off, as this will prevent proper re-installation after servicing. Coil up the surplus cable and tuck the coils out of the way. © 2013 Superior Fires Ltd.
  • Page 10: Checking The Burner & Spark Gap

    Re-fit the glass panel using 4 M6 screws. The fire is designed to operate correctly with the supplied components according to the instructions. Never add coals. Never put combustible or non-combustible materials, rub- bish or other matter into the fire. © 2013 Superior Fires Ltd.
  • Page 11: Fitting Decorative Hood/Frame

    In the event that the inlet pressure is not in accordance with the figures stated in the data section of these instructions, the appliance must not be commissioned, and the problem investigated and rectified. © 2013 Superior Fires Ltd.
  • Page 12: Briefing The Customer

    BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT. Modifications are dangerous and can have seri- ous unseen effects on safety. If the pilot will not stay lit there is a problem with dirt, the gas supply to it, or the thermocouple needs replacement. Re-assembly in the reverse of removal. © 2013 Superior Fires Ltd..
  • Page 13: Pilot Assembly

    It is important to note that the appliance can never be expected to be 100% smoke tight and small quantities of smoke may be seen in corners of joints and gasket faces etc without affecting safety when the fire is in operation. © 2013 Superior Fires Ltd.
  • Page 14: Troubleshooting Guide

    • Leakage occurring. Carry out leakage test and rectify any problems. • Combustible materials used in incorrect positions. • Airborne substances such as cleaning materials/air fresheners are being drawn through the fire. • Other airborne contaminants such as dust, tobacco smoke, paint vapours. © 2013 Superior Fires Ltd.
  • Page 15 This fire is supplied with a particular style of fire front. Use of the fire front will ensure an adequate airflow under the firebox for the correct functioning of this appliance. Compliance with safety standards cannot be guaranteed when another style of front is used. © 2013 Superior Fires Ltd.
  • Page 16 This appliance is intended as a secondary source of heat only and should not be used in a room without some form of back- ground heating present. If the appliance is used in a room as the sole source of heat, then condensation may occur on colder sur- faces within the room. © 2013 Superior Fires Ltd.
  • Page 17 Re-fit the glass panel using 4 M6 screws. The fire is designed to operate correctly with the supplied components according to the instructions. Never add coals. Never put combustible or non-combustible materials, rub- bish or other matter into the fire. © 2013 Superior Fires Ltd.
  • Page 18 The appliance should be checked on an annual basis to ensure it is working safely and that there is no excessive build up of soot. The frequency of service will depend on usage, but MUST be carried out at least once annually. Servicing must be carried out by a competent person, such as a GAS SAFE registered installer. © 2013 Superior Fires Ltd.
  • Page 19 GAS SAFE No. : Contact details of Engineer As our policy is one of continuous improvement and development , we hope therefore you will understand we must retain the right to amend details and/or specifications without prior notice. © 2013 Superior Fires Ltd.

Table of Contents