superior fires F500384 Installation & User's Instructions

Radiant/convector inset gas fire

Advertisement

INSTALLATION & USER INSTRUCTIONS
RADIANT/CONVECTOR INSET GAS FIRE
Superior Fires
Christchurch, Dorset BH23 2BT
Tel: 01202 588 632
Fax: 01202 499326
www.superiorfires.co.uk
e : info@superiorfires.co.uk
MARLFIELD SLIMLINE RADIANT
ASABA CONTEMPORARY SLIMLINE CONVECTOR
IN THE UK ALWAYS USE A GAS SAFE REGISTERED ENGINEER TO INSTALL, REPAIR OR SERVICE THIS APPLIANCE
Please note : Except where otherwise stated, all rights, including
copyright in the text, images and layout of this booklet is owned by
Superior Fires Ltd. You are not permitted to copy or adapt any of the
content without the prior written permission of Superior Fires Ltd.
MODELS COVERED BY THESE INSTRUCTIONS
MARLFIELD SLIMLINE RADIANT
KINLOCH SLIMLINE RADIANT
CHEWTON GROVE BRASS SLIMLINE RADIANT
CHEWTON GROVE BLACK SLIMLINE RADIANT
CHEWTON GROVE CHROME SLIMLINE RADIANT
ASABA CONTEMPORARY SLIMLINE CONVECTOR
ASABA CONTEMPORARY BLACK SLIMLINE CONVECTOR
ASABA GROVE BRASS SLIMLINE CONVECTOR
ASABA GROVE BLACK SLIMLINE CONVECTOR
ASABA GROVE CHROME SLIMLINE CONVECTOR
ASABA ELEGANCE BRASS SLIMLINE CONVECTOR
ASABA ELEGANCE BLACK SLIMLINE CONVECTOR
ASABA ELEGANCE BRASS/BLK SLIMLINE CONVECTOR
CHEWTON SOHO SLIMLINE RADIANT
CHEWTON SOHO BLACK SLIMLINE RADIANT
MARLFIELD SLIMLINE RADIANT TC
KINLOCH SLIMLINE RADIANT TC
CHEWTON GROVE SLIMLINE RADIANT TC
CHEWTON SOHO SLIMLINE RADIANT TC
*TC = 'TOP CONTROL' OR 'SLIDE CONTROL'
KINLOCH SLIMLINE RADIANT
ASABA GROVE SLIMLINE CONVECTOR
1
*
*
*
*
CHEWTON GROVE SLIMLINE RADIANT
ASABA ELEGANCE SLIMLINE CONVECTOR
All instructions must be handed to the user for
safekeeping.
Revision C - 10/12
GB IE
F500384
F500385
F500386
F500550
F500551/2
F500388
F500556
F500557
F500558
F500389
BS 7977-1 : 2009
BS EN 509 : 2000
F500553
KM579168
F500555
F500554
F500387
F500387
F500479
F500480
F500481
F500482
CHEWTON SOHO SLIMLINE RADIANT
© 2012 Superior Fires Ltd.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F500384 and is the answer not in the manual?

Questions and answers

Summary of Contents for superior fires F500384

  • Page 1 Superior Fires Ltd. You are not permitted to copy or adapt any of the content without the prior written permission of Superior Fires Ltd. Revision C - 10/12...
  • Page 2: Table Of Contents

    • Remote control models : These appliances features a battery-operated control system, and under normal usage will need a new battery approximately every twelve months. Refer to the appropriate section of these instructions for details of how to change the battery. © 2012 Superior Fires Ltd.
  • Page 3: Appliance Data

    Opening DEPTH should be 200mm or greater for a clay/cement lined or Pre-cast flue which is new, unused, or previously used only with a gas appliance. DEPTH should be 240mm or greater for a flue used for solid fuel of oil burning appliances. Opening DEPTHS include any plaster or infill panels which form part of the installation. © 2012 Superior Fires Ltd.
  • Page 4: Debris Collection Space

    CLAY/CEMENT LINES OR BLOCK FLUE WHICH IS NEW, UNUSED, OR PREVIOUSLY ONLY USED WITH A GAS FIRE. X Dimension = 20mm UNLINED FLUE OR CHIMNEY WHICH HAS BEEN PREVIOUSLY USED FOR A SOLID FUEL OR OIL BURNING APPLIANCE X Dimension = 60mm © 2012 Superior Fires Ltd.
  • Page 5: Ventilation

    Self tapping screw pack; 4 No.8 x 5/16 Spigot restrictor Deflector baffle Set of manufacturers instructions Slide control position marking sticker (slide control models only) Slide control knob and M4 Nyloc nut (slide control models only) © 2012 Superior Fires Ltd.
  • Page 6: Preparing The Appliance

    8mm sup- ply pipe should be temporarily sealed to prevent the ingress of debris during fixing. © 2012 Superior Fires Ltd.
  • Page 7: Gas Supply Routing

    Now disconnect the inlet restrictor elbow from the inlet pipe. Connect the previously installed gas supply to inlet restrictor elbow, and re-fit the restrictor elbow to the inlet pipe of the appliance. Figure 10 © 2012 Superior Fires Ltd. FIN:...
  • Page 8: Gas Connection

    Continue pressing down the knob while turning further to the left to activate the piezo spark, continue to hold the knob down for a further 10 seconds after the pilot has been lit. If the pilot does not light repeat the previous steps. © 2012 Superior Fires Ltd.
  • Page 9: Operating The Fire (Slide Control)

    MUST be of a type supplied for the purpose by the appliance manufacturer. If the fire is not spilling, then further guidance should be sought, using the Troubleshooting section as a guide. © 2012 Superior Fires Ltd.
  • Page 10: Testing For Spillage

    15. Check any purpose provided ventilation is un-obstructed. 16. Light the fire and test for spillage. 17. Check the operating pressure (see section 16.5) and safe operation of the appliance. For specific servicing instructions, see the relevant sections. © 2012 Superior Fires Ltd.
  • Page 11: Cleaning The Ceramics

    Ensure appliance is off and cool. The battery is located in the front of the ignition unit, on the right hand side of the burner (shown in figure 20). Unscrew the battery holder cap. Insert 1 x ‘AA’ (1.5 volt) battery. Replace cap. Figure 20 © 2012 Superior Fires Ltd.
  • Page 12: Troubleshooting Guide

    • Spillage occurring. Carry out Spillage test and rectify any problems. • Combustible materials used in incorrect positions. • Firebox grommet seal missing, rectify. • Other airborne contaminants such as dust, tobacco smoke, paint vapours. © 2012 Superior Fires Ltd.
  • Page 13: Clearances To Combustibles

    For Republic of Ireland, ventilation may be required, see IS 813, ICP3, IS 327, and any other rules in force. WARNING :Ventilation openings (where fitted) must never be blocked or restricted in any way. © 2012 Superior Fires Ltd.
  • Page 14: Operating The Fire - Manual Control

    Switch the appliance OFF, call in your installer to check any ventilation and carry out any remedial work required. DO NOT allow the appliance to be used until the installation is passed as safe. © 2012 Superior Fires Ltd.
  • Page 15: Fuel Bed Layout - Ripped Coal Effect

    Place the large brick panel against the rear of the firebox. Figure 11 Place the ceramic combustion matrix onto the burner and the ceramic side cheeks onto the matrix. © 2012 Superior Fires Ltd.
  • Page 16: Fuel Bed Layout - Rounded Coal Effect

    Figure 18 Place the middle row of four coals onto the supports in the matrix, over the top of the holes. Ensure the coals are not turned sideways, such that they actually enter the holes. © 2012 Superior Fires Ltd.
  • Page 17: Servicing

    Ensure appliance is off and cool. The battery is located in the front of the ignition unit, on the right hand side of the burner (shown in figure 20). Unscrew the battery holder cap. Insert 1 x ‘AA’ (1.5 volt) battery. Replace cap. Figure 20 © 2012 Superior Fires Ltd.
  • Page 18: List Of Replacement Parts

    TRAY108 Remote handset and receiver kit F730003/5 11.0 INSTALLATION DETAILS Name & contact details of installer : Supplied by : Installer GAS SAFE registration No : Model : Fire serial No. : Date installed : © 2012 Superior Fires Ltd.
  • Page 19: Service History

    GAS SAFE No. : Contact details of Engineer As our policy is one of continuous improvement and development , we hope therefore you will understand we must retain the right to amend details and/or specifications without prior notice. © 2012 Superior Fires Ltd.