Step 5: Contact Technical Support; Power Supply Failure; Step 1: Identify The Failed Power Supply; Step 2: Unplug The Power Cord - M86 Security Threat Analysis Reporter User Manual

Table of Contents

Advertisement

A
S
A
C
PPENDICES
ECTION
PPENDIX

Step 5: Contact Technical Support

Contact Technical Support to order a new replacement hard
drive and for instructions on returning your failed hard drive
to M86 Security.

Power supply failure

Step 1: Identify the failed power supply

The administrator of the server is alerted to a power supply
failure on the chassis by an audible alarm and an amber
power supply LED—or an unlit LED—on the front and rear
of the chassis.
NOTE: A steady amber power supply LED also may indicate a
disconnected or loose power supply cord. Verify that the power
supply cord is plugged in completely before removing a power
supply.
WARNING: Be sure the correct failed power supply has been
identified. Removing the wrong power supply will cause the
system to crash.

Step 2: Unplug the power cord

To prevent electrical shock to yourself and damage to the
unit, unplug the power cord from the failed power supply.