B. Constructing the Appliance Chase
A chase is a vertical boxlike structure built to enclose the
gas appliance and/or its vent system. Vertical vents that run
on the outside of a building may be, but are not required
to be, installed inside a chase.
Construction of the chase may vary with the type of building.
These instructions are not substitutes for the requirements
of local building codes. Local building codes MUST be
checked.
Chases should be constructed in the manner of all outside
walls of the home to prevent cold air drafting problems.
The chase should not break the outside building envelope
in any manner.
Walls, ceiling, base plate and cantilever fl oor of the chase
should be insulated. Vapor and air infi ltration barriers
should be installed in the chase as per regional codes for
the rest of the home. Additionally, in regions where cold
air infi ltration may be an issue, the inside surfaces may be
sheetrocked and taped for maximum air tightness.
To further prevent drafts, the wall shield and ceiling fi re-
stops should be caulked with high temperature caulk to seal
B
D
A
Rough
Rough
Opening
Opening
(Vent Pipe)
(Height)
Inches
10
46-3/4
mm
254
1187
Figure 3.2 Clearances to Combustibles
8
A
C
CLEARANCES TO COMBUSTIBLES:
B
C
D
E
Rough
Rough
Clearance
Opening
Opening
to Ceiling
(Depth)
(Width)
22
49
32
559
1245
813
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. o • 12/07
gaps. Gas line holes and other openings should be caulked
with high temp caulk or stuffed with unfaced insulation. If
the appliance is being installed on a cement slab, a layer of
plywood may be placed underneath to prevent conducting
cold up into the room.
C. Clearances
Fire Risk.
Odor Risk.
• Install appliance on hard metal or wood surfaces
extending full width and depth of appliance.
• Do NOT install appliance directly on carpeting,
vinyl, tile or any combustible material other than
wood.
Fire Risk.
• Construct chase to all clearance specifi cations
in manual.
• Locate and install appliance to all clearance
specifi cations in manual
FROM TOP OF
HOOD TO CEILING
E
F
J
K
G
F
G
Combustible
Combustible Floor
Flooring
Appliance
0
0
0
0
WARNING
WARNING
I
H
I
J
Floor to Top
Behind
Sides of
of Access
Appliance
Panel
1/2
1/2
4
13
13
102
H
K
Front of
Appliance
36
914