1. Flange Back Adjustment (Using the minipattern box)

The flange back of inner focus lens is adjusted automatically. If
shifted, the auto focus is disordered.
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Note 1: Dark Siemens star chart.
Note 2: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Preparations before adjustments:
1) The minipattern box is installed as shown in the following fig-
ure.
Note 3: The attachment lenses are not used.
Note 4: Take care not to hit the mini-pattern box when
extending the lens.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage ± 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
6) Check that the data on page: F, address: 14 to 25 and 87 to 9B
are initial value (See table below).
Address
Data
Address
14
33
21
15
48
22
16
DA
23
17
DF
24
18
13
25
19
C0
87
1A
00
88
1B
00
89
1C
00
8A
1D
00
8B
1E
00
8C
1F
00
8D
20
20
8E
CAMERA
Siemens star chart with ND filter
for minipattern box (Note 1)
Check operation on the LCD
screen
F
14 to 25, 87 to 9B
Data
Address
Data
20
8F
BA
90
46
91
0A
92
00
93
FF
94
00
95
00
96
00
97
00
98
00
99
00
9A
00
9B
Specified voltage: The specified voltage varies according to the
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Adjusting method:
Order Page Address Data
1
0
2
00
3
6
00
4
6
00
5
6
00
6
F
00
Note 5: The adjustment data will be automatically input to page:
00
F, address: 14 to 25 and 87 to 9B.
00
00
Processing after Completing Adjustment:
00
Order Page Address Data
00
1
6
00
2
00
00
3
0
4
– 7 –
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the mini-
pattern box.
Below 3 cm
Minipattern box
Regulated power supply
Output voltage : Specified voltage ± 0.01 Vdc
Output current : more than 3.5 A
Need not connected
Fig. 5-1-13
Procedure
01
01
Perform "Data setting during
camera system adjustments".
(Refer to page 5-14)
01
13
Press PAUSE button.
01
27
Press PAUSE button. (Note 5)
02
Check the data changes to "01".
87
Check the data changes to "00".
Procedure
01
00
Press PAUSE button.
Release the data setting
performed at step 2. (Refer to
page 5-14)
01
00
Perform"Flange Back Check".