Flange Back Adjustment (Using Minipattern Box); Flange Back Adjustment - Sony DSC-F505 Service Manual

Hide thumbs Also See for DSC-F505:
Table of Contents

Advertisement

2. Flange Back Adjustment

(Using Minipattern Box)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Mode
STILL
Subject
Siemens star chart with ND filter for
the minipattern box (Note1)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
14 to 25
Note 1: Dark Siemens star chart.
Note 2: Check that the data of page: 6, address: 02 is "00". If not, turn the
power of the unit OFF/ON.
Preparations before adjustments:
The minipattern box is installed as shown in the following figure.
Note: The attachment lenses are not used.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjust the power supply
output voltage to the specified voltage
written on the sheet which is supplied with
the minipattern box.
Minipattern box
Regulated power supply
Output voltage: Specified voltage ± 0.01Vdc
Output current: more than 3.5A
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Need not connected
Black (GND)
Fig.5-1-13.
Below 3 cm
Camera
Table
5-23
Adjusting method:
1)
Install the minipattern box so that the distance between it and
the front of the lens of the camera is less than 3cm.
2)
Make the height of the minipattern box and the camcorder equal.
3)
Check that the output voltage of the regulated power supply is
the specified voltage ± 0.01Vdc.
4)
Select page: 0, address: 01, and set data: 01.
5)
Select page: 5, address: F1, and set data: FF.
6)
Check that the center of the Siemens star chart and center of
the exposure screen coincide.
7)
Check that the data of page: F, address: 14 to 25 is the initial
value (See table below).
Address
Data
Address
1A
14
1C
15
94
1B
1C
16
26
17
EC
1D
1E
18
13
19
B9
1F
8)
Select page: 6, address: 01, set data: 13, and press the PAUSE
button of the adjustment remote commander.
9)
Select page: 6, address: 01, set data: 27, and press the PAUSE
button.
(The adjustment data will be automatically input to page: F,
addresses: 14 to 25.)
10) Select page: 6, address: 02, and check that the data is changed
to "01".
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
2)
Select page: 5, address: F1, and set data: 00.
3)
Select page: 0, address: 01, and set data: 00.
4)
Perform "Flange Back Check".
Data
Address
Data
00
20
20
00
21
20
00
22
23
00
23
44
46
24
0A
00
25
00