Flange Back Adjustment (Using The Minipattern Box) - Sony DSC-S70 Service Manual

Hide thumbs Also See for DSC-S70:
Table of Contents

Advertisement

1. Flange Back Adjustment
(Using the minipattern box)
The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual forcusing.
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Note 1: Dark Siemens star chart.
Note 2: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Preparations before adjustments:
The minipattern box is installed as shown in the following figure.
Note 3: The attachment lenses are not used.
Note 4: Take care not to hit the minipattern box when extending
the lens.
Specified voltage: The specified voltage varies according to the
minipatternbox, so adjustment the power sup
ply output voltage to the specified voltage
written on the sheet which is supplied with the
minipattern box.
Minipattern box
Output voltage : Specified voltage ±0.01Vdc
Output current : more than 3.5A
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Fig. 5-1-12
STILL
Siemens star chart with ND filter
for minipattern box (Note 1)
Check operation on TV monitor
F
14 to 25, 88 to 9B
Below 3 cm
Camera
Camera
table
Regulated power supply
Need not connected
Adjusting method:
1)
Install the minipattern box so that the distance between it
and the front of lens of the camera is less than 3cm.
2)
Make the height of minipattern box and the camera equal.
3)
Check the output voltage of the regulated power supply is
the specified voltage ± 0.01 Vdc.
4)
Check that the center of Siemens star chart meets the center
of shot image screen with the zoom lens at TELE end and
WIDE end respectively.
5)
Select page: 0, address: 01, and set data: 01.
6)
Select page: 5, address: F1, and set data: FF.
7)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
8)
Perform " Data setting during camera system adjustment".
(Refer to page 5-13)
9)
Check that the data on page: F, addresses: 14 to 25, 88 to 9B
are initial values (See table below).
Address
Data
14
36
15
48
16
DA
17
DF
18
16
19
00
1A
00
1B
00
1C
00
1D
00
1E
00
1F
00
20
20
10) Select page: 6, address: 01, set data: 13, and press the PAUSE
button.
11) Select page: 6, address: 01, set data: 27, and press the PAUSE
button. (The flange back adjustment is performed and the
adjustment data is stored in page: F, address: 14 to 25, 88 to
9B)
12) Select page: 6, address: 02, and check that the data is "01".
Processing after completion of adjustment:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
2)
Select page: 5, address: F1, and set data: 00.
3)
Select page: D, address: 63, set data: 00, and press the PAUSE
button.
4)
Release the data setting performed at step 8).
(Refer to page 5-13)
5)
Select page: 0, address: 01, and set data: 00.
6)
Perform "Flange Back Check".
5-14
Address
Data
Address
21
20
90
22
BA
91
23
46
92
24
0A
93
25
00
94
88
00
95
89
00
96
8A
00
97
8B
00
98
8C
00
99
8D
00
9A
8E
00
9B
8F
00
Data
00
00
00
00
00
00
00
00
00
00
00
00

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cybershot dsc-s70

Table of Contents