Fault Message Output
4
Fault Message Output
When a fault occurs, power indicator/fault indicator (6) blinks RED.
Next to that, a fault message is shown on the display of the control panel.
The meaning of the messages is shown in the following table.
Depending on the type of fault, you may need to visit a Webasto Service Centre.
If serious malfunctions such as overheating or failure to start reoccur, the heater is
locked and can be put back into service by deleting the failures.
Do this by disconnecting the power supply:
1
Ensure that the heater/fan is not running (to be established by the sound of the
heater operating).
If necessary wait until fans stop running.
2
Switch off the Dual Top Evo by pressing the On/Off button
3
Remove the 15 A fuse (red cable). Wait at least 5 seconds and insert the fuse
again.
Now the heater is reset.
Please note that different fault messages (fault message numbers) occur in each case
for the various control panel types.
22
.
NOTE
Dual Top Evo 6