Ieee Standards - Dell S4820T Installation Manual

Hide thumbs Also See for S4820T:
Table of Contents

Advertisement

Parameter
Reliability
NOTE: The table below represents the DC PSU's capabilities and does not represent S4820T
operation.
The power supply operates within all specified limits over the following input voltage range.
Table 9. DC Input Specification
Parameter
Min/max input voltage range
Maximum power consumption
Typical power consumption
Input power at full load
Input current at full load
Start up VDC
Start off VDC 37.5

IEEE Standards

The S4820T switch complies with the following IEEE standards:
802.1AB LLDP
802.1ag Connectivity fault Management
802.1D Bridging, STP
802.1p L2 Prioritization
802.1Q VLAN Tagging, Double VLAN Tagging, GVRP
802.1s MSTP
802.1w RSTP
802.3ab Gigabit Ethernet (1000BASE-T)
802.3ac Frame Extensions for VLAN Tagging
802.3ad Link Aggregation with LACP
802.3ae 10 Gigabit Ethernet (10GBASE-X)
802.3ba 40 Gigabit Ethernet (40GBase-SR4, 40GBase-CR4) on optical ports
802.3u Fast Ethernet (100BASE-TX)
802.3x Flow Control
802.3z Gigabit Ethernet (1000BASE-X)
ANSI/TIA-1057 (LLDP-MED)
48
Specifications
MTBF 355,178 hours
Specifications
−40.5V /−48V/ −60V
800 Watts
338 Watts
−40.5V/970W −48V/930W −60V/950W (without
fans)
−40.5V/980W −48V/940W −60V/960W (with fans)
−40.5V/23.8A −48V/19.0A −60V/15.6A (without
fans)
−40.5V/24A −48V/19.2A −60V/16.0A (with fans)
39.0 +/− 1.5V
37.5 +/− 1.5V
Technical Specifications

Advertisement

Table of Contents
loading

Table of Contents