Connecting to the DSX-1 Interface

Procedure
1. Connect the 8-position modular plug end of the DSX cable to the DSX-1 interface. If
your DSX cable has a DB15 end, use a DSX-1 adapter.
Refer to the pin assignment information in the iMarc SLV Technical Description to
ensure you have proper connections.
2. Connect the other end of the cable to the CPE (customer premises equipment, like
a PBX).
3. Tighten the screws on each side of the connector to secure the cable.
POWER
4. Verify that the DSX signal (SIG) LED is green, and that the DSX out-of-frame (OOF)
and alarm (ALM) LEDs are off. If so, the DSX interface is set up correctly and is
operational. If not, make sure both ends of the DSX cable are properly seated.
When ALM is on, contact the service provider.
5. Check Health and Status messages in the left column of the System and Test
Status screen.
Main Menu → Status → System and Test Status
If any DSX-1 messages appear, refer to the status information in the iMarc SLV
Operations Guide.