(2,1) -1- 599685B DD60S TALL installA2 NZGB.indd 6/7/09 3:48:15 PM
(2,1) -1- 599685B DD60S TALL installA2 NZGB.indd 6/7/09 3:48:15 PM
4

PARTS SUPPLIED

Drain hose
Drain hose
Wire clip (1)
support (1)
joiner (1)
If the Drain hose supplied is not long enough to reach your services, you must use a Drain Hose Extension Kit P/N 525798 which will extend the drain hose by 3.6m. The kit is available from the nearest Fisher & Paykel
Authorised Service Centre or our local website listed at the end of this document.

5 CAVITY PREPARATION

These marks indicate formed bracket screw locations.
*
Preferred position. If adequate clearance, services hole can be higher.
If hole is higher, ensure drain hose is routed straight into the waste connection.
Water Connection
Recommended COLD (Maximum 60°C).
¾ " BSP (GB20) to suit flat washer.
Water Pressure
Water softener models
1 MPa (145 psi)
Other models
1 MPa (145 psi)
Drains will need to be separated to satisfy kosher requirements.
We suggest you confirm acceptability with your local rabbi in
respect to kosher installations.
Side mounting
Top mounting
bracket kit
brackets (2)
(A and B) (2)
OPTIONAL
OPTIONAL
Max
Min
0.1 MPa (14.5 psi)
0.03 MPa (4.3 psi)
Clamp (1)
Phillips
38 mm
16 mm
bottom
screws (7)
fixing screws
& metal
washers (2)
Moisture
10 mm
protection
tape must
be applied.
min. ø
60 mm
*
Important!
Adjacent cabinetry must not
extend above cavity base
Rubber
Cavity bracket
Moisture protection
washer for
kit (1)
tape (1)
inlet hose (1)
(to prevent moisture
damage)
n b e lo c
r v ic e s c a
N o t e : S e
D r a w e r ®
e o f D is h
e it h e r s id
*
max.
450 mm
Water supply
min.
220-240 VAC
min. 4.5 A
a t e d
.
200 mm