SHUTTING DOWN & CLEAN-UP
Step 1
Remove detergent suction
tube from container and
insert into 1 gallon of fresh
water. Siphon water at low
pressure for one minute.
8
Step 5
Disconnect the garden hose
from the water inlet on the
unit.
TAKING A BREAK... five minutes or more

WINTERIZING AND LONG-TERM STORAGE

1. Disconnect all water connections.
2. Turn on the machine for a few seconds,
until the water which had remained in
the pump exits. Turn off immediately.
3. Do not allow high pressure hose to
become kinked.
Step 2
Turn the switch to
off (O) position and
unplug cord from
outlet.
Step 6
Disconnect the high pressure
hose from the high pressure
outlet.
Step 1
Engage the gun
safety lock.
Step 3
Turn off the water
source.
4. Store the machine and accessories in
a room which does not reach freezing
temperatures. DO NOT store near
furnance or other sources of heat as it
may dry out the pump seals.
Caution: Failure to follow the above
directions will result in damage to the
pump assembly and accessories.
Step 4
Press trigger to
release water
pressure.
Step 7
Engage the gun
safety lock.
Step 2
Turn pressure washer
to off (O) position.