Installation
Figure 5. Route the wiring bundle as appropriate. The rear connector plate should be attached to
the mounting frame before installing the frame in the instrument panel. The rear connector
plate can be used to tie down the cable assemblies. Use the supplied edge guard to protect the
cable from sharp edges. Connect the shield grounds directly to the connector mounting plate.
Once the cable assemblies, the connector mounting plate, and the mounting frame are
assembled, install the mounting frame assembly in the instrument panel. Be sure to use low
profile head screws so the unit will slide in and out freely. Attach the front of the mounting
frame to the instrument panel. Use support brackets to attach the rear of the frame to the
aircraft.
M
T
OUNTING
UBE
Care must be taken when installing the mounting tube to ensure you can properly insert and
secure the unit. There must be a minimum vertical spacing of 0.040 inches between units to
prevent interference with the cam locking mechanisms. Mounting tubes with clearance
dimples help maintain the proper clearance. The mounting tube must be installed with the
clearance dimples pointing up.
Figure 3 - Full Stack Mounting Tube Spacing
The mounting tube should be flush to the instrument panel and allow sufficient clearance for the
back of the bezel of the unit to mount flush to the mounting tube. Sufficient clearance must exist
in the instrument panel opening to allow ease of insertion and removal of the unit. If the back