Pin No.
Pin Name
38
A2
39
A3
40
A4
41
A5
42
A6
43
A7
44
VSS
45
A8
46
A9
47
A10
48
A11
49
A12
50
A13
51
A14
52
A15
53
A16
54
A17
55
A18
56
A19
57
VSS
58
MUTE
59
SMUTE
60
EMP-O
61
NCO
62
STBY
63
SYSRES
64
BU-IN
65
VSS
66
X-IN
67
EX-IN
68
VDD
69
AS
70
RD
71
HWR
72
LWR
73
MD0
74
MD1
75
MD2
76
AVDD
77
AVREF
78
NIH
I/O
O
O
O
Address signal output to the flash memory (IC401, 402)
O
O
O
Ground terminal
O
O
O
O
O
O
Address signal output to the flash memory (IC401, 402)
O
O
O
O
O
O
Ground terminal
Relay drive signal output for the speaker protect relay (RY1101, 1201, 1301)
O
At output of "L", the relay is turned on to apply muting
O
Soft mute control signal output to the electrical volume (IC1106, 1206, 1306) "H": mute on
O
Emphasis control signal output to the digital filter (IC1101, 1201, 1301) "H": emphasis on
O
System clock signal output terminal Not used (open)
I
Standby signal input terminal Fixed at "H" in this set
System reset signal input from the reset signal generator (IC303) and bus interface (IC306) (for
I
SONY bus) "L": reset For several hundreds msec. after the power supply rises, "L" is input,
then it changes to "H"
I
Backup power supply detect signal input terminal (used also to reset standby)
Ground terminal
I
System clock input terminal (14.74 MHz)
I
System clock input terminal (14.74 MHz)
Power supply terminal (+5V)
O
Address strobe signal output terminal Not used (open)
Strobe signal output for data reading to the digital signal processor (IC101, 201 CXD2711Q)
O
and flash memory (IC401, 402)
Strobe signal output for upper byte data writing to the digital signal processor (IC101, 201
O
CXD2711Q) and flash memory (IC402)
O
Strobe signal output for lower byte data writing to the flash memory (IC401)
I
Input terminal for setting microcomputer operation mode (fixed at "L")
I
Input terminal for setting microcomputer operation mode (fixed at "H")
I
Input terminal for setting microcomputer operation mode (fixed at "H")
Power supply terminal (+5V) (for A/D conversion)
I
Reference voltage input terminal (+5V) (for A/D conversion)
I
Fixed at "H" in this set
Function
– 72 –

Hide quick links: