Table 5-1 REPEATER SETUP PARAMETERS
Response
1-20
1-399
None
FSK
RS232
FSK Blank & Burst
TIC
VNC
0, 1
Yes, No
Yes, No
Yes, No
0 = disabled
1-60 min
15 characters/numbers
UPPER CASE
0 = disabled (default)
1-250, 253
0 = disabled
1-250,
254 (default)
25-75, 75-160
AC or DC
Yes, No
Yes, No
Each repeater is assigned a Home Repeater number from 1-
20.
Each repeater is programmed with a number of the channel
that it is operating on.
Data signaling type for RNT, FSK, RS232 or FSK B&B.
None=LTR dispatch only.
TIC is for Telephone Interface Card w/o RNT.
VNC=network telephone interconnect w/o RNT.
Same as value of the Area bit in the mobiles.
Not used.
Select if the repeater is not connected to additional repeaters
(via HSDB).
Not used.
Time between CWID transmissions.
Station call letters.
Group ID transmitted when the local microphone PTT is
active.
Group ID transmitted when the Repeater is in the Test Mode.
Power level in watts for transmit power.
The type of primary power source for the Repeater.
Select if a paging terminal is installed.
Select if the Data Modem option is installed.
5-2