Mitsubishi PKA-RP35GAL Service Manual page 26

Pka/pkh series split-type, heat pump air conditioners split-type, air conditioners, r470c/r410a indoor unit
Table of Contents

Advertisement

9-6. HOW TO CHECK THE PARTS
PKH-P35GALH, PKH-P50GALH
PKA-RP35GAL, PKA-RP50GAL
Parts name
Room temperature
Disconnect the connector then measure the resistance using a tester.
thermistor
(TH1)
(Surrounding temperature 10:~30:)
Pipe temperature
thermistor
(TH2)
Condenser/evaporator
temperature thermistor
(TH5)
Fan motor
Measure the resistance between the terminals using a tester.
(Winding temperature 20:)
Relay connector
3
Red
1
White
2
2
1
Black
3
Protector
OFF:125i5:
ON :79i15:
Measure the resistance between the terminals using a tester.
Vane motor
4
(Surrounding temperature 20:~30:)
Orange
5
M
Red
2
Pink
Yellow Brown Blue
3 6 1
Measure the resistance of each heater element by using a tester.
Heater
(Only PKH)
Contactor
Measure the resistance between the terminals using a tester.
(for heater)
(Only PKH)
<Thermistor Characteristic graph>
Thermistor for
lower temperature
Thermistor R
=15kΩ ± 3%
0
Fixed number of B=3480 ± 2%
Rt=15exp { 3480(
273+t
0:
15kΩ
10:
9.6kΩ
20:
6.3kΩ
25:
5.4kΩ
30:
4.3kΩ
40:
3.0kΩ
Normal
4.3k"~9.6k"
Open or short
Motor terminal
or
Relay connector
Red–Black
White–Black
Connector
Brown–Yellow
Brown–Blue
Red–Orange
Red–Pink
Normal
72"
800W 240V
Normal
6
1
88H
160"
Room temperature thermistor(TH1)
Pipe temperature thermistor(TH2)
Condenser/evaporator temperature
thermistor(TH5)
1
1
) }
273
Check points
Abnormal
(Refer to <Thermistor Characteristic graph>
for a detail.)
Normal
120.5"
Open or short
111.3"
Normal
186~214"
Open or short
Abnormal
Open or short
Abnormal
Open or short
26
Abnormal
Abnormal
< Thermistor for lower temperature >
50
40
30
20
10
0
-20 -10 0
10 20 30 40 50
Temperature (:)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents