Contec CMS-50E User Manual page 10

Hide thumbs Also See for CMS-50E:
Table of Contents

Advertisement

a short push (click). There are four modes of data display that can be viewed.
Press the power button with a prolonged push (1 second) to enter the Settings Menu Interface (see
Figure 4 ). Please
Please
Note:
Note: When the display direction on the screen is in the Portrait View, you can not
Please Note:
enter the Menu Interface, click the power button to switch to Landscape View.
The user can setup the following parameters in the Settings Menu – Backlight Brightness, Alarm
high-low limits, data transmission, data storage (recording), data upload to computer.
note in the Settings Menu:
CLICK = short press of power button and PRESS
CLICK
CLICK
a) a) a) Backlight
Backlight
Backlight adjustment
adjustment
adjustment
On the main menu interface, click the power button to select "Brightness", Press the power button
and hold to adjust the backlight brightness.
b) b) b) Alarm
Alarm
setting
Alarm setting
setting
On the main menu interface, click the power button to select "Alarm", Press the power button (1sec)
to enter the alarm setting interface as shown in Figure 5:
a. a. a. Adjust
Adjust
ing
the
high
Adjusting
ing the
the high
high and
Click the power button to select "Dir", then Press the button to choose Up or Down (this will be the
direction the value of the high-low limits of SpO
To raise the SpO
and pulse rate limit, choose "Dir" as 'Up', then Click the power button to highlight
2
the parameter to be adjusted: SpO
Pulse rate high limit (PR ALM HI), Pulse rate low limit (PR ALM LO), Press the power button and
hold to adjust the selected limit to the desired higher value and release the power button once the
higher limit has been reached.
To lower the SpO
and pulse rate limit, choose "Dir" as 'Down', then Click the power button to
2
choose the parameter to be adjusted. Press the power button and hold to adjust the selected limit to the
desired lower value and release the power button once the lower limit has been reached.
If If If the
the
alarm
function
function is is is on
the alarm
alarm function
data of of of SpO
data
data
SpO
SpO
or or or pulse
pulse
pulse rate
2 2 2
Figure 4 Main Menu Interface
and
low
limits s s of of of alarm
limit
alarm
alarms s s
and low
low limit
high limit (SPO
2
on, , , the
on
the
device
will
the device
device will
will provide
rate
rate is is is beyond
beyond
beyond the
the limit
the
limit and
limit
PRESS
PRESS = prolonged push of power button (1sec)
and pulse rate will be adjusted)
2
ALM HI), SpO
2
provide
midium-priority
provide midium-priority
midium-priority alarm
and intermittent
and
intermittent alarm
intermittent
alarm
alarm will
7
low limit (SPO
ALM LO),
2
2
alarm
signal
when
alarm signal
signal when
when the
will occur.
will
occur.
occur.
Please
the
the

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents