Installation and User Manual FONDA
ELECTRIC SAUNA HEATER:
0315-44-040518
0315-66-040518
0315-80-040518

CONTROL PANEL:

1601-27 (T1)
314 SKCP 1-3 C

Advertisement

Table of Contents
loading

Summary of Contents for Helo 0315-44-040518

  • Page 1: Control Panel

    Installation and User Manual FONDA ELECTRIC SAUNA HEATER: 0315-44-040518 0315-66-040518 0315-80-040518 CONTROL PANEL: 1601-27 (T1) 314 SKCP 1-3 C...
  • Page 2: Table Of Contents

    Installation and User Manual FONDA Contents 1. Quick instructions for use of the sauna heater 1.1. Check before taking a sauna bath 1.2. Operation of the sauna heater controls 2. Information for users 2.1. Sauna room 2.2. Rekommenderad ventilation i bastun 2.3.
  • Page 3: Quick Instructions For Use Of The Sauna Heater

    1.2. Operation of the sauna heater controls Refer to the specific control panel operating instructions. For additional information about enjoying a sauna bath, please visit our website at www.helo.fi 2. Information for users Persons with reduced physical and mental capacity, sensory handicap, or little experience and knowledge about how the device is operated (e.g.
  • Page 4: Rekommenderad Ventilation I Bastun

    Installation and User Manual FONDA 2.2. Rekommenderad ventilation i bastun 1000 mm 500 mm Image. 1 Recommended sauna room ventilation 1. Sauna room 3. Electric sauna heater 5. Exhaust flue or channel 2. Washroom 4. Exhaust valve 6. Door to the sauna room 7.
  • Page 5: Sauna Heater Stones

    Installation and User Manual FONDA 2.4. Sauna heater stones Quality stones meet the following requirements: - Sauna stones should withstand heat and heat variation caused by vaporisation of the water thrown on the stones. - Stones should be rinsed before use in order to avoid odour and dust. - Sauna stones should have an uneven surface to supply a larger surface for the water to evaporate from.
  • Page 6: Preparing For Sauna Heater Installation

    Installation and User Manual FONDA 3. Preparing for sauna heater installation Check the following before installing the sauna heater. The ratio of the heater's input (kW) and the sauna room's volume (m ). Volume recommendations are presented in Table 1 on page 8. The minimum and maximum volumes must not be exceeded. The sauna room height must be a min.
  • Page 7: Installation Steps

    Installation and User Manual FONDA 3.2 Installation steps 1. Secure the wall mounts in the wall with the accompanying screws (6 x 40 and 6 x 16). Note the heater’s minimum clearance. If the sauna heater is going to be fitted with legs you don't need to attach the bottom brackets.
  • Page 8: Safety Distances

    Installation and User Manual FONDA Safety distances (mm) (mm) **) = Se section 3.4 *) = Absolute measure 20 min min 20 min 30 30 min Image. 2 Safety clearances Adequate amount Power Saunaroom Safety clearances min. of stones Volym On the sides In front Till tak...
  • Page 9: Installation Of Control Unit And Sensor

    Installation and User Manual FONDA 3.4 Installation of control unit and sensor The control unit has been connected electrically by a cable to the sauna heater. The control unit must be installed outside the sauna room. The sensor is mounted to the sauna wall, directly on the centre line of the sauna heater, 40 mm from the ceiling. NOTE! If the wall on which the sensor is to be installed is made of highly heat insulating material (e.g.
  • Page 10: Locating The Connecting Box For The Connection Cable In The Sauna Room

    Installation and User Manual FONDA 3.6 Locating the connecting box for the connection cable in the sauna room Sauna heater Image. 3 Location for the connection box A = Specified minimum safety clearance 1. Recommended location for the connecting box 2.
  • Page 11: Principle Image When T1 Is Used As Control Panel

    Installation and User Manual FONDA Installations- och bruksanvisning FONDA 3.7 Principle image when T1 is used as control panel Connector strip Limiter Heater Sensor cable 1 Blue 1 Blue 2 White 2 White 3 Red 3 Red 4 Yellow 4 Yellow Valk White Weiss...
  • Page 12: Wiring Diagram

    Installation and User Manual FONDA Wiring diagram Teho, Effekt Lämpövastukset, Värmeelement, Tennid, Heating elements, Input, Potencia Heizeelement, Resistores Térmicos, Éléments chauffants, Leistung, Moc Elementy grzewcze, ТЭНы, Vöimsus,Wejscie Puissance 230 V власть SEPC SEPC SEPC 4,4 kW 230V - 240V 1N~ / 2~ 2200W 2200 W 2667 W...
  • Page 13: Rohs

    Installation and User Manual FONDA 2. ROHS Ympäristönsuojeluun liittyviä ohjeita Anvisningar för miljöskydd Tämän tuotteen käyttöiän päätyttyä sitä ei Denna produkt får inte kastas med saa hävittää normaalin talousjätteen vanliga hushållssopor när den mukana, vaan se on toimitettava inte längre används. Istället ska den sähkö- ja elektroniikkalaitteiden kierrätykseen levereras till en återvinningsplats tarkoitettuun keräyspisteeseen.