BMC and DRAC5 Firmware Version Requirements

When upgrading either the BMC or the DRAC5, you must update the
firmware for both components to ensure full functionality and compatibility.
For example, the power reduction feature of the DRAC5 version 1.40
firmware works only when BMC 2.27 or higher is also installed. If the BMC
and DRAC firmware are incompatible—BMC 2.27 installed with DRAC5
version 1.33 or BMC 1.79 installed with DRAC5 version 1.40—the power
reduction feature may not function correctly.

Back Cooling Fans

Systems manufactured after September 2008 no longer include the four back
cooling fans installed in earlier systems. Therefore, BMC version 2.27 does
not recognize the presence of back fans. The back fans will still run in older
systems; however, from a system perspective, the fans do not exist and are
not monitored. As a result, if the back fans fail, the SEL, server management
software, and remote access card will not log the error. This change does not
compromise the standard hot plug and redundancy features of the front fans.
New LCD Error Codes
The following LCD error codes have been added for your system. For a
complete list of error codes, see "About Your System" in your Hardware
Owner's Manual.
Table 1. LCD Status Messages
Code
Test
EB107 Proc
Machine
Check Error
EB113 PCIE Fatal
Error
Slot XX
Causes
CPU detected an
unrecoverable hardware
error.
CPU detected an
unrecoverable hardware
error.
Corrective Actions
See error EB113 for specific
information on what
hardware failed.
"XX" indicates the slot
associated with the failed
hardware. If you are unable
to resolve the issue, see
"Getting Help" in your
Hardware Owner's Manual.