Bmc/Bios Version Info - Dell PowerEdge C6145 Using Instructions

Using the baseboard management controller
Hide thumbs Also See for PowerEdge C6145:
Table of Contents

Advertisement

 
Example:
1
Get LAN Configuration Parameter command:
ipmitool raw 0xC0 0x02 0x01 0x14 0x00 0x00
Response: 0x00 0x11 0x01 0x80 (VLAN Enable and VLAN ID: 1)
2
Set LAN Configuration Parameter command:
ipmitool raw 0xC0 0x01 0x01 0x14 0x01 0x80
Response: 0x00

BMC/BIOS Version Info

BMC Version Info
Get Device ID command can get BMC version Info in response date byte4, 5.
More detail about this command please refers to "IPMI SPEC v2.0 errata
revision 4" chapter 20.1.
Response Date
Data field
Byte 1
Completion Code
Byte 2
Device ID.
Byte 3
Device Revision
[7] 1 = device provides Device SDRs
0 = device does not provide Device SDRs
[6:4] reserved. Return as 0.
[3:0] Device Revision, binary encoded.
 
Appendix
74
VLAN ID matches the VLAN ID value
given in this parameter.
[6:4] - reserved
[3:0] - most significant four bits of the
VLAN ID

Advertisement

Table of Contents
loading

Table of Contents