Download Print this page

Stile Preparation - Kaba E-PLEX 3x65 Deadlatch/Exit Mortise Installation Instructions Manual

Narrow stile lock

Advertisement

B. STILE PREPARATION
B-1 Install the Kaba Cam Plug d1 or d2 into the Deadlatch or Deadbolt. Face of
Cam Plug must be flush or below the surface of the stile, make sure set
screw is snug but do not tighen it yet. (See Figure 2 on page 3).
Note: Refer to the Adams Rite Cam Plug Instructions for Right Hand/Left
Hand Installations (located in the Screw Pack). (For Deadlatch Models)
B-2 Affix the appropriate model Template to the outside face of the door stile.
Ensure the pins from the Cam Plug are through the proper holes, the tem-
plate is straight and aligned with the edge of the door, and that "TOP" is
facing up and "BOTTOM" is facing down (See Figure 3).
B-3 With a center punch or awl, mark the four drilling points.
B-4 Utilizing a power drill with
through the door (interior and exterior of the stile). Tip—you may want to
first, drill pilot holes, then drill from each side to keep holes straight
through and minimize burrs.
Flush or
Below
3
" drill bit, drill four holes as marked completely
8
For
Deadlatch
Model, use
template
64782.
For Deadbolt
Model, use
template
64783.
Figure 3
5

Hide quick links:

Advertisement

loading