Page 1
SSP-369-FE-CAC6.00-ISSUE4.0 SERVICE MANUAL MODEL SSP-369-FE STAINLESS STEEL PANEL TELEPHONE EQUIPPED WITH CAC6.00 FIRMWARE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street & Engineering Company Okeechobee, FL 34972 Voice: 863-357-0798 Fax: 863-357-0006...
ISSUE 4.0 IMPORTANT INFORMATION CUSTOMER Please fill in before you continue. The following information is necessary when calling CEECO for assistance. MODEL NUMBER MODEL SSP-369-FE EQUIPPED WITH CAC6.00 FIRMWARE SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you, please have this information available when calling for technical support.
RECOMMENDED TOOLS AND TEST EQUIPMENT ........15 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS ....16 SPECIFICATIONS....................17 PARTS LIST ......................18 FCC NOTICE......................19 10.0 REPAIR AND RETURN INFORMATION............20 11.0 WARRANTY POLICY ..................21 12.0 DIAGRAM......................22 CEECO Communication Equipment & Engineering Company PROPRIETARY...
ISSUE 4.0 INTRODUCTION The practices in this manual provide installation and maintenance information for the CEECO Model SSP-369-FE Stainless Steel Panel Telephone, equipped with CAC6.00 software For information not included in this manual, please call or write: CEECO Customer Service...
Example: Entering #00 followed by 101003 would program the phone to have no call restrictions, no incoming call allowed, a wide dial tone detect window, a muted microphone initially, DTMF dialing, and a 5 minute automatic timed call disconnect. CEECO Communication Equipment & Engineering Company PROPRIETARY...
9=30 min.call timeout • Be sure to record your selections in the table below for future reference. Telephone Options Table: #00 __ __ __ __ __ __ 1 2 3 4 5 6 CEECO Communication Equipment & Engineering Company PROPRIETARY...
Page 7
ISSUE 4.0 DIAGRAM-PROGRAMMING KEYPAD LOCATION: CEECO Communication Equipment & Engineering Company PROPRIETARY...
40 speed-dial locations available (#30 thru #69). The speed numbers may be up eleven digits in length. Example: Entering #305551212 will cause the phone to automatically dial the number 555-1212, when # 3 0 is entered on the normal keypad. CEECO Communication Equipment & Engineering Company PROPRIETARY...
Page 11
ISSUE 4.0 NORMALLY CONFIGURED KEYPAD: CEECO Communication Equipment & Engineering Company PROPRIETARY...
Programming is now completed. Hang up the phone and return the mini- jumpers to the “OFF” position, as depicted on the last page of this manual. The phone is now ready for Testing/Operation. CEECO Communication Equipment & Engineering Company PROPRIETARY...
(three short beeps) and reset the line. If not, hang up and repeat sections 3.2, 3.3, 3.5, 3.10, and 3.11 only. If this does not solve the problem, please refer to section 10.2. CEECO Communication Equipment & Engineering Company PROPRIETARY...
1/4" Nut Driver 5/16" Nut Driver Volt/Ohm Meter Flat Blade Screw Driver Security Tool 301-037 *The security tool is for a standard 5/32∀ button-head screw generally used on the framework of telephone booth. CEECO Communication Equipment & Engineering Company PROPRIETARY...
Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations. Use caution when installing or modifying telephone lines. CEECO Communication Equipment & Engineering Company PROPRIETARY...
DIMENSIONS: 10.12" Wide x 13.12" High x 2.75" Deep MOUNTING: Vertical surface mount MEMORY RETENTION: Lithium Battery – Long Life FCC REGISTRATION: BW88T7-13823-TE-T UL LISTED NO.: 6OF5 RINGER EQUIVALENCE: 0.8A TYPE JACK: RJ11C CEECO Communication Equipment & Engineering Company PROPRIETARY...
FCC registration number and ringer equivalence number. These numbers are listed in section 9.00. The FCC further requires that you notify your local telephone company when permanently disconnecting this telephone. CEECO Communication Equipment & Engineering Company PROPRIETARY...
10.3 NON-WARRANTY REPAIR: CEECO will repair equipment out of warranty for a set charge plus parts. The customer must pay the shipping costs both directions. 10.4 RETURN FOR CREDIT: Material may be returned for credit only with prior approval. Material authorized for return is subject to a 20% restocking charge based on the manufacturer’s list price.
CEECO will repair or replace any unit during this period if found to be defective for reasons other than abuse and improper use or improper installation.
BEFORE POSITION GOING OFF HOOK When programming is completed, move the mini jumpers to the OFF position. NOTE: Do not leave the mini jumpers in the ON position; this will decrease battery life. CEECO Communication Equipment & Engineering Company PROPRIETARY...