Focal Point Envy Installation And User Instructions Manual

Focal Point Envy Installation And User Instructions Manual

Flueless high efficiency gas fire

Advertisement

Quick Links

ENVY
EUPHORIA
FLUELESS H H IGH E E FFICIENCY G G AS F F IRE
INSTALLATION A A ND
USER I I NSTRUCTIONS
All i i nstructions m m ust b b e h h anded t t o u u ser f f or s s afekeeping
Revision A - 08/07
Country(s) of destination - GB/IE
Focal Point Fires plc, Avon Trading Park, Christchurch, Dorset BH23 2BT
Tel: 01202 499330
Fax: 01202 499326
www.focalpointfires.co.uk
e-mail: sales@focalpointfires.co.uk

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Envy and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Focal Point Envy

  • Page 1 All i i nstructions m m ust b b e h h anded t t o u u ser f f or s s afekeeping Revision A - 08/07 Country(s) of destination - GB/IE Focal Point Fires plc, Avon Trading Park, Christchurch, Dorset BH23 2BT Tel: 01202 499330 Fax: 01202 499326 www.focalpointfires.co.uk...
  • Page 2 Envy Euphoria © 2007 Focal Point Fires plc.
  • Page 3: Table Of Contents

    Please n n ote: Except where otherwise stated, all rights, including copyright in the text, images and layout of this booklet, is owned by Focal Point Fires plc. You are not permitted to copy or adapt any of the content without the prior written permission of Focal Point Fires plc.
  • Page 4: Appliance D D Ata

    APPLIANCE D D ATA Envy a a nd E E uphoria m m odels Gas Group G20 Natural Gas CAT I2H Inlet Pressure (± 2.0mbar) 20 mbar Regulator Pressure Max Energy Input (Gross) 2.3 kW Max Energy Input (Net) 2.07 kW 0.23 m 3 /h...
  • Page 5: Installation Method

    Basic o o pening s s izes ( ( all d d imensions i i n m m m) The basic opening dimensions for the appliance are as follows; Dimension: Euphoria m m odels Envy m m odels ‘a’ minimum ‘a’ maximum ‘b’ minimum ‘a’...
  • Page 6 It is important in these circumstances that any vapour control barrier is not damaged, and that any structural members of the house frame are not dam- aged - refer to section 6.5. © 2007 Focal Point Fires plc.
  • Page 7: Ventilation

    Coal Set (Front & Rear) (Euphoria models) Rubber grommet Cable fixing kit Screw pack Envy screw pack consists of: No. 8 pozi self tapping screws Euphoria screw pack consists of: No. 8 pozi self tapping screws M5 x 7 screws APPLIANCE I I NSTALLATION Note: E E ns s ure t t hat t t he g g as s s s upply i i s s i i s s olated b b efore c c ommenc c ing g i i ns s tallation o o f t t he a a pplianc c e.
  • Page 8 75mm air gap at the sides and rear and 100mm air gap above the firebox. Alternatively the firebox may be insu- lated with 75mm of fibre glass wool or rock wool to the sides, rear and 100 mm to the top. © 2007 Focal Point Fires plc.
  • Page 9 The hearth may now be put in place (If fitted). Again this should not bridge the cavity where it projects into the wall space. Finally install the fireplace or fire surround and back panel/marble to its finished location. © 2007 Focal Point Fires plc.
  • Page 10: Installation Method 1

    It is also a good idea to enable as much airflow as possible, into and out of the area behind the fire without causing excessive heat loss from the room when the fire is off. © 2007 Focal Point Fires plc.
  • Page 11: Final F F Itting

    Refer to section 6.4 (recessing into a non-combustible wall). Envy m m odels : : If the appliance is to be wall mounted then the entire base of the appliance must be supported by a non-combustible shelf. It may be desirable for the shape of the shelf to follow the profile of the appliance.
  • Page 12: Checking The Burner & Spark Gap

    CHECKING T T HE B B URNER A A ND S S PARK G G AP Envy m m odels o o nly : : There are no imitation fuel bed components to install. The appliance features a ribbon burn- er which is designed to produce a continuous band of flame over it’s length.
  • Page 13: Fitting Decorative Hood/Frame

    The firefront shown in these instructions may differ form the one supplied with the appliance. Envy m m odels : : Hang the decorative facia assembly onto the firebox as shown in figure 19. Secure in posi- tion using two no.8 self tapping screws as shown in figure 20.
  • Page 14: Setting Pressure

    15. Check any purpose provided ventilation is un-obstructed. 16. Light the fire and check setting pressures. 17. Carry out combustion check as per section 9.4. 17. Check safe operation of the appliance. For specific servicing instructions, see relevant sections. © 2007 Focal Point Fires plc.
  • Page 15: Cleaning The Coals

    MUST not be done. Replacements must be original manufacturers parts. Re-assemble in the reverse of removal. Ensure setting pressures are as stated in Section 2; Appliance Data. © 2007 Focal Point Fires plc.
  • Page 16: Catalyst

    It is important to note that the appliance can never be expected to be 100% smoke tight and small quantities of smoke may be seen in corners of joints and gasket faces etc without affecting safety when the fire is in operation. © 2007 Focal Point Fires plc.
  • Page 17: Troubleshooting G G Uide

    Fire s s mells w w hen f f irst l l it o o r i i n u u se Newness smell from brand new appliance. Leakage occurring - Carry out leakage test and rectify any problems. Low temperature sealants or combustible materials used in incor- rect positions. © 2007 Focal Point Fires plc.
  • Page 18 This appliance is only suitable for the gas type for which it is supplied. WARNING: Due to the nature of this product the area around the top of the appliance (i.e. the grille) gets very hot. Care should be taken when operating the appliance. © 2007 Focal Point Fires plc.
  • Page 19 It should be established that any mirrors or picture frames etc. to be positioned on the wall above the appliance are able to withstand prolonged exposure to moderate heat and moisture before proceeding with their installa- tion. © 2007 Focal Point Fires plc.
  • Page 20 NOT allow the appliance to be used until the appliance and installation is passed as safe. If the pilot continues to be extinguished you must call your installer to check the operation of the complete appliance. © 2007 Focal Point Fires plc.
  • Page 21 The Installation instructions carry full servicing details for the use of the installer. PART N N O. ITEM FB/F550272 Glass door assembly FB/F550241 Hood (Envy models) FB/F550234 Hood (Euphoria models) FR/F820191 Decorative facia assembly (Envy models) FR/F820190 Decorative frame (Euphoria models) FR/F800035 Firefront (Euphoria models) FT/003155/0 Gas Valve FT/F730023 Pilot assembly FT/F510018...