Message
Invalid Gatekeeper Address.
Saving log failed.
Invalid Operation. Initial
setting is not completed.
System Error!
Please restart the system.
If error message appears
again, please contact Installer
or Service Administrator.

Miscellaneous

Problem
"Safe Mode" is displayed on
the screen.
Note
When "Safe Mode" is
displayed on the
screen, you cannot
connect to the
network, make video
conference calls, or
perform certain
settings (self
diagnosis, performing
a network test, etc.).
The format of the gatekeeper's IP address that you entered is invalid.
Enter the gatekeeper IP address correctly, in the format
XXX.XXX.XXX.XXX (decimal values separated by periods). For values
of only 1 or 2 digits, enter these numbers as they are. Do not enter like
[.001].
Example: The IP address is [192.168.0.1].
Correct entry: [192.168.0.1]
Wrong entry: [192.168.000.001]
Multicast or broadcast addresses cannot be used.
You are using a USB memory device that is not compatible with the
unit.
Use a USB memory device compatible with the unit (Page 114).
There is not enough free space on the USB memory device you are
using.
Confirm the USB memory device has sufficient free space (at least
5 MB) before using it.
In local site settings, you tried to select and save a connection mode
without completing network settings.
Before making local site settings, change the connection mode
(Page 108) and make network settings (Page 91).
The unit's internal software failed to start up.
The unit failed to write data to the internal flash memory.
Reset the unit by turning off its power, then turning it back on. If the
same message is displayed after resetting the unit, contact your dealer.
A standard definition (640 ´ 480p, 720 ´ 480p) video camera signal has
been detected.
Disconnect the video camera from the unit, and reset the unit by turning
off its power, then turning it back on. Check to make sure the video
camera's resolution is set to HD (1920 ´ 1080i), and then connect the
video camera to the unit again.
A standard definition (640 ´ 480p, 720 ´ 480p) display signal has been
detected.
Disconnect the display from the unit, and reset the unit by turning off its
power, then turning it back on. Make sure to connect a HD (1920 ´
1080i) display to the unit.
The field frequency of the video camera or display you are using is
different from the field frequency setting of the unit.
Use a video camera or display that has the same field frequency as the
unit. For details, contact your dealer.