12.1.4 Heating operation

12.1.4.1
Thermostat control
• Compressor is OFF when Intake Air Temperature - Internal Setting Temperature > +2.0℃
• Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature<
Compressor OFF point -0.5K.

12.1.5 Automatic Operation

• Once AUTO mode is selected, operation mode is determined by set temperature of remote control and indoor
intake temperature.
1st judgment
JUDGE CONDITION
If indoor intake temp – Remote control
temp setting ≥ +2
If -2 ≤ indoor intake temp. – Remote
control Temp. setting ≤ +2
If indoor intake temp. – Remote control
temp. setting < -2
Intake temp.- setting temp.
2nd & following judgment (every 10 minutes after 1st judgment)
Cool mode
Dry mode
Heat mode
HEAT
DRY
-6 -5 -4 -3 -2 -1 0
REFERANCE MODE
COOL
1
2
3
4
26
5
6

Hide quick links: