Outdoor Unit Electronic Controller Complete Removal Procedure - Panasonic CS-RE9NKR Service Manual

Hide thumbs Also See for CS-RE9NKR:
Table of Contents

Advertisement

15.2 Outdoor Unit Electronic Controller Complete Removal Procedure

1.
Take off the terminal cover by releasing the 3 screws. Disconnect the 7 wires from the terminal and then the 3
screws fixed between terminal supporting panel and c-box casing can be released.
2.
Release the 8 pieces screws on top panel, and remove the top panel.
screws
screws
screws
3.
Release L shape front panel by releasing the 8 pieces screws
Screws
4.
Disconnect the wires from CN-HOT, CN-TH,CN-TANK connector on outdoor PCB, fan motor wire connector,
and wires from reactor.
Screws of
terminal
cover
Screws
Screws
41
Disconnect wires from the
terminal
CN-HOT, CN-TH, CN-TANK connector
on PCB
Reactor.
Fan motor wire
connector

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-re12nkrCu-re9nkrCu-re12nkr

Table of Contents