AG 2100

Resetting the AG 2100

Resetting Administrative Login Name and Password

The AG 2100 resets the administrative Login Name and password to "admin" and "admin"
respectively when the reset button is clicked 3 times in a 2 second window. When the trigger
for this event is detected, the device
Updates the login name and password
Writes all settings to current.txt
Performs a warm reboot.

Resetting Settings to Factory Defaults

The AG 2100 resets the current settings to factory defaults when the reset button is clicked five
times in a two second window. When the trigger for this event is detected the device will:
Rename the existing current.txt to current.bak (an existing current.bak is discarded if
present)
Creates a new current.txt file containing the exact copy of the factory.txt file
Performs a warm reboot.
See
"Importing the Factory Defaults {Factory}" on page 211.

Warm Reboot

The device performs a warm reboot if the reset button is clicked fewer than three times (i.e.,
one or two) in a 2 second window.

Other Cases

In all other cases (in terms of the number of clicks of the reset button), no action is taken.