3 Pan calibration is most useful when multiple fixtures are stacked vertically. To calibrate, set zoom, focus, iris,
and tilt position for easy one-over-the-other comparison and set each fixture to the same pan DMX value.
Select one fixture to be the reference fixture. On the other fixtures, select
[Enter]. Adjust the offset as necessary to align the beam with the reference beam. Press [Enter] to save the
setting.
4 Tilt calibration is most useful when multiple fixtures are arranged horizontally. To calibrate, set zoom, focus,
iris, and pan position for easy side-by-side comparison and set each fixture to the same tilt DMX value.
Select one fixture to be the reference fixture. On the other fixtures, select
[Enter]. Adjust the offset as necessary to align the beam with the reference beam. Press [Enter] to save the
setting.
5 To calibrate the dimmer, select
lens. Set the offset to 0 and then increase it until light is clearly projected onto the paper. Press [Enter] to
save the setting. Remove the paper.
6 To calibrate color mixing flags (cyan, magenta, yellow, and color temperature correction), project white
beams with no dimming and position them for easy comparison. On each fixture, including the reference,
select
U TI L /C A L/ C O F
be the reference. Adjust the offsets on the other fixtures to match the reference color. Press [Enter] to save
the setting. Repeat for
7 Focus calibration is useful when two or more fixtures are the same distance from a projection surface. To
calibrate focus, set up all fixtures with the same focus, zoom, dimming, iris, and gobo values. Select a
focussed fixture to be the reference. On the other fixtures, select
Adjust the offset to focus the image. Press [Enter] to save the setting.
Software upload
The software update mode is normally engaged automatically by the upload device. See Software installation on
page 24.
16
Figure 12: Zoom calibration point
U TI L /C AL / D O F
and press [Enter]. (This adds a defined amount of cyan.) Select one fixture to
M OF
(magenta),
Y OF
MAC 2000 Profile II
U TI L /C A L/ P OF
U TI L /C A L/ T OF
and press [Enter]. Hold a piece of paper over the
(yellow), and
C TO F
(CTC).
UT IL / CA L/ F OO F
and press
and press
and press [Enter].