Set Line Rate

To set the cam era's line rate u se the line rate p aram eter, p art of the Cam era Controls set. This featu re can
only be u sed w hen the cam era is in Internal m od e —that is, w hen the start line trigger is d isabled (Trigger
Mod e Off).
N ote: A line rate < 1 / (Exp osu re tim e + 1 µs) w ill retu rn an error (―Invalid Param eter‖) if this cond ition
is not m et. You m u st ad ju st these tw o p aram eters in the correct sequ en ce to m aintain this cond ition.
If the external line rate exceed s the m axim u m line rate allow ed for a m od e, the cam era w ill continu e to
ou tp u t d ata at its m axim u m line rate. Thou gh no im age artefacts associated w ith over -sp eed w ill occu r,
you m ay notice that u nd er over-sp eed cond itions the im age w ill ap p ear com p ressed and the ap p arent
d istan ce travelled w ill be red u ced .
Parameter
Line Rate (in H z)
Camera Link Configuration
Base, 8-bit, 12 bit
Med iu m , 8-bit, 12bit
Full, 8-bit
Teledyne DALSA
Camera Control
Cam era line rate in a range from 1 H z u p to 80 kH z.
This featu re is only available w hen the cam era is in Internal Mod e—
line trigger is d isabled (Trigger Mod e off).
Line Rates
37.5kH z (4K), 75 kH z (2K)
75 kH z(4K), 80 kH z (2K)
80 kH z (4K), 80 kH z (2K)
Description
Maximum Line Rate
33
03-032-20206-00