Camera Link Configuration; Trigger Modes; Exposure Controls - Teledyne Linea User Manual

2k and 4k monochrome cmos line scan
Table of Contents

Advertisement

Linea 2K and 4K Monochrome Line Scan Camera User's Manual
The factory setting is the cam era settings that w ere ship p ed w ith the cam era and w hich load ed d u ring the
cam era's first p ow er-u p . To load or restore the origin al factory settings, at any tim e, select the Factory
Setting p aram eter and then select the User Set Load p aram eter.
N ote: By d efau lt, the u ser settings are set to the factory settings.
Default Setting
Either the Factory or one of the User settings can be u sed as the Defau lt Setting by selecting the set in the
User Set Defau lt Selector. The chosen set au tom atically becom es the d efau lt settin g and is the set load ed
w hen the cam era is reset of p ow ered u p .

Camera Link Configuration

Name
Base
Med ium
Full
*Set Pixel Form at (nu m ber of bits p er p ixel)

Trigger Modes

The cam era's im age exp osu res are initiated by a trigger event. The trigger event is either a p rogram m able
internal signal u sed in free ru nning m od e, an external inp u t u sed for syn chronizing exp osu res to external
triggers, or a p rogram m ed fu n ction call m essage by th e controlling com p u ter. These triggering m od es are
d escribed below .
Internal trigger (trigger disabled): The cam era free-ru nning m od e has a p rogram m able internal
tim er for line rate and a p rogram m able exp osu re p eriod .
External trigger (trigger enabled): Exp osu res are controlled by an external trigger signal. The
external trigger signal is the Cam era Link control line CC1.

Exposure Controls

The Exposure Control modes define how and when the camera will capture an image—the integration
period. The integration period is the amount of time the camera's sensor is exposed to incoming light
before the captured image is transmitted to the controlling computer.
Exposure control is defined as the start of exposure and exposure duration.
The start of exposure can be an internal timer signal (free-running mode) or an external trigger
signal.
The exposure duration can be programmable (such as the case of an internal timer) or controlled by the
external trigger pulse width.
The cam era can grab im ages in one of three w ays. You d eterm ine the three im aging m od es u sing a
com bination of the Exp osu re Mod e p aram eters (inclu d ing I/ O p aram eters), Exp osu re Tim e and Line Rate
p aram eters.
Teledyne DALSA
Taps
2
4
8
SPF*
8, 12
8, 12
8
29